DEATH VALLEY, CA ·
OSHA Inspection: NATIONAL PARK SERVICE, DEATH VALLEY NATIONAL PARK
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL PARK SERVICE, DEATH VALLEY NATIONAL PARK in 579 COW CREEK SERVICE RD. HWY 190, DEATH VALLEY, CA 92328 (NAICS 712190). OSHA activity number 339018020.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL PARK SERVICE, DEATH VALLEY NATIONAL PARK
- Site address
- 579 COW CREEK SERVICE RD. HWY 190
- City
- DEATH VALLEY
- State
- CA
- ZIP
- 92328
- Mailing
- PO BOX 579 HWY 190, DEATH VALLEY, CA 92328
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 712190
- Employees
- 130
- Ownership type
- Federal government (D)
Citations
9 citations on file for this inspection.
1910.157 C01
- Issued
- May 30, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: At the Death Valley National Park Auto repair shop there was a 10 lb fire extinguisher obscured from vision by other equipment and sitting on shop floor.
Recent events (1)
- · Z (S) $0
1910.212 B
- Issued
- May 30, 2013
- Abate by
- Jun 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) At the Cow Creek, Death Valley National Park wood work shop there was a Chiuting fifteen (15) inch planer not anchored to the shop floor. b) At the Cow Creek, Death Valley National Park Auto repair shop there was a Dewalt fourteen (14) inch Chop saw, serial no. 144331 not anchored to the work table.
Recent events (1)
- · Z (S) $0
1910.215 A04
- Issued
- May 30, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: At the Death Valley National Park auto repair shop there was a bench grinder with the work rest adjusted to one-fourth inch from wheel periphery.
Recent events (1)
- · Z (S) $0
1910.243 B02
- Issued
- May 30, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.243(b)(2): Airhose and hose connections used for conducting compressed air to utilization equipment was not designed for the pressure and service to which they were subjected. At the Death Valley National Park Auto repair shop there was a 95 psi air hose used to air up large truck tires that was dry rotted with visable cracks on hose.
Recent events (1)
- · Z (S) $0
1910.244 A02 VI
- Issued
- May 30, 2013
- Abate by
- Jun 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.244(a)(2)(vi): Each jack used constantly or intermittently at a single locality was not thoroughly inspected at least once every six months: a) At the Death Valley National Park Auto repair shop there was a Wheeltronic LLC, model no. EELR343A hydraulic jack lift used to lift vehicles that had not been inspected for more than six months. b) At the Death Valley National Park Auto repair shop there was eight visable jack stands, and various other wheeled and un-wheeled floor jacks that had not been inspected in more than six months. c) At the Death Valley National Park Auto repair shop there was an un-inspected jack stand that had been overloaded causing the ratchet to break off and then it was repaired by welding it back on.
Recent events (1)
- · Z (S) $0
1910.303 B01
- Issued
- May 30, 2013
- Abate by
- May 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1): a) At the Death Valley National Park, Auto repair shop battery charging room there was a portable battery charger positive charge clamp with exposed wire on the operating handle. b) At the Death Valley National Park, Auto repair shop there was a portable battery charger with the cord jacket separated at the plug end exposing insulated cord wires.
Recent events (1)
- · Z (S) $0
1910.303 B02
- Issued
- May 30, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: At the Death Valley National Park Information Technology office there was an energized re-locatable power tap permanently secured with screws to the room wall.
Recent events (1)
- · Z (S) $0
1910.304 B04 II B
- Issued
- May 30, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle supplied a total cord- and plug-connected load in excess of the maximum specified in Table S-4: a) At the Death Valley National Park, Accounting and Information Technology building, there was a microwave, 2.0 sq. ft. refrigerator, paper shredder and other appliances plugged to an energized re-locatable power tap and extension cord. b) At the Death Valley National Park, Resource office building, there was a 1.7 cu. ft. refrigerator plugged to an energized orange extension cord then plugged to a re-locatable power tap plugged to wall outlet.
Recent events (1)
- · Z (S) $0
1910.305 J01 I
- Issued
- May 30, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact: At the Cow Creek, Death Valley National Park Auto repair shop an energized bench grinder did not have a light bulb.
Recent events (1)
- · Z (S) $0
More inspections at National Park Service, Death Valley National Park
View National Park Service, Death Valley National Park's full OSHA safety record →
More inspections in this industry (NAICS 712190)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339018020.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.