WINDER, GA —
OSHA Inspection: SOUTHEAST CULVERT, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of SOUTHEAST CULVERT, INC. in 1094 BANKHEAD HIGHWAY, WINDER, GA 30680 (NAICS 332996). OSHA activity number 339018517.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOUTHEAST CULVERT, INC.
- Site address
- 1094 BANKHEAD HIGHWAY
- City
- WINDER
- State
- GA
- ZIP
- 30680
- Mailing
- PO BOX 999, AUBURN, GA 30011
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332996
- Employees
- 61
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.95 I05
- Issued
- May 9, 2013
- Abate by
- Jun 26, 2013
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.95(i)(5): The employer did not ensure proper initial fitting and supervise the correct use of all hearing protectors: Southeast Culvert, Inc. - on or about April 26, 2013, employees wore ear plugs due to high noise levels in the plastic manufactring facility and metal manufacturing facility, but did not use them correctly. Ear plugs were observed protruding from the ear of several employees. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (O) $0
- — Z (S) $3500
1910.1200 F05
- Issued
- May 9, 2013
- Abate by
- Jun 26, 2013
- Penalty
- Initial $2,100 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: Southeast Culvert, Inc. - on or about April 26, 2013, containers of diesel fuel were not labeled as to the contents and the hazards associated with them. The CSHO observed abatement of this hazard during the inspection. Abatement Observed: YES
Recent events (2)
- — I (S) $1800
- — Z (S) $2100
1910.134 C02 I
- Issued
- May 9, 2013
- Abate by
- Jun 26, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: Southeast Culvert, Inc. - on or about April 26, 2013, employees used half face air purifying respirators and filtering facepiece respirators when welding. Use was voluntary, but employees had not trained on information contained in Appendix D of the Respiratory Protection standard. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 C02 II
- Issued
- May 9, 2013
- Abate by
- Jun 26, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION/CONDITION) (DESCRIBE HAZARD) Southeast Culvert, Inc. - on or about April 26, 2013, employees used half face air purifying respirators and filtering facepiece respirators when welding. Use was voluntary, but the employer did not perform medical evaluations or ensure that employers cleaned, stored, and maintained respirators properly. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Southeast Culvert, INC.
View Southeast Culvert, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332996)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339018517.