Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOUTHEAST CULVERT, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SOUTHEAST CULVERT, INC. in 1094 BANKHEAD HIGHWAY, WINDER, GA 30680 (NAICS 332996). OSHA activity number 339018517.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southeast Culvert, INC. — free Get an email when a new federal OSHA severe-injury report for Southeast Culvert, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1094 BANKHEAD HIGHWAY
City
WINDER
State
GA
ZIP
30680
Mailing
PO BOX 999, AUBURN, GA 30011
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332996
Employees
61
Ownership type
A

4 citations on file for this inspection.

1910.95 I05

Other-than-serious 2 instances 10 exposed
Issued
May 9, 2013
Abate by
Jun 26, 2013
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.95(i)(5): The employer did not ensure proper initial fitting and supervise the correct use of all hearing protectors:  Southeast Culvert, Inc. - on or about April 26, 2013, employees wore ear plugs due to high noise levels in the plastic manufactring facility and metal manufacturing facility, but did not use them correctly.  Ear plugs were observed protruding from the ear of several employees.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3500

1910.1200 F05

Serious Gravity 1 1 instance 10 exposed
Issued
May 9, 2013
Abate by
Jun 26, 2013
Penalty
Initial $2,100 · Current $1,800 Reduced
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein:   Southeast Culvert, Inc. - on or about April 26, 2013, containers of diesel fuel were not labeled as to the contents and the hazards associated with them.  The CSHO observed abatement of this hazard during the inspection. Abatement Observed: YES
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2100

1910.134 C02 I

Other-than-serious 1 instance 2 exposed
Issued
May 9, 2013
Abate by
Jun 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  Southeast Culvert, Inc. - on or about April 26, 2013, employees used half face air purifying respirators and filtering facepiece respirators when welding.  Use was voluntary, but employees had not trained on information contained in Appendix D of the Respiratory Protection standard.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C02 II

Other-than-serious 1 instance 1 exposed
Issued
May 9, 2013
Abate by
Jun 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION/CONDITION) (DESCRIBE HAZARD)   Southeast Culvert, Inc. - on or about April 26, 2013, employees used half face air purifying respirators and filtering facepiece respirators when welding.  Use was voluntary, but the employer did not perform medical evaluations or ensure that employers cleaned, stored, and maintained respirators properly.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Southeast Culvert, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339018517.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.