HOUSTON, TX —
OSHA Inspection: FRANCISCO MENDOSA CHAVEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FRANCISCO MENDOSA CHAVEZ in 7801 WESTHEIMER ROAD, HOUSTON, TX 77063 (NAICS 238140). OSHA activity number 339019226.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FRANCISCO MENDOSA CHAVEZ
- Site address
- 7801 WESTHEIMER ROAD
- City
- HOUSTON
- State
- TX
- ZIP
- 77063
- Mailing
- 6114 RENWICK DRIVE #125B, HOUSTON, TX 77081
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.404 B01 II
- Issued
- Apr 23, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which were in use by employees did not have approved ground fault circuit interrupers for personal protection: (a) at The Fish and the Knife, located at 7801 Westheimer Rd., Houston, TX, employees were exposed to electrical hazards when using the temporary power pole outlets, to power the stucco mixing drill without a ground fault circuit interrupter (GFCI).
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.405 D
- Issued
- Apr 23, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(d): Panelboards mounted in cabinets, cutout boxes or enclosures designed for the purpose were not dead front: (a) at The Fish and the Knife, located at 7801 Westheimer Rd., Houston, TX, employees were exposed to electrical hazards when using the temproray power pole due to exposed live parts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02 I
- Issued
- Apr 23, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement: (a) at 7801 Westheimer Rd., Houston, TX, Fish and the Knife, employees were exposed to fall hazards when using an unleveled, 6 foot, 4 inch, walk through fabricated frame scaffold to apply stucco.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1926.451 C02 II
- Issued
- Apr 23, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: (a) at 7801 Westheimer Rd., Houston, TX, Fish and the Knife, employees were exposed to fall hazards when using an unleveled, 6 foot, 4 inch, walk through fabricated frame scaffold to apply stucco.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Apr 23, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: (a) at 7801 Westheimer Rd., Houston, TX, Fish and the Knife, employees were exposed to fall hazards when using a 6 foot, 4 inch, walk through fabricated frame scaffold, without proper access and egress, to apply stucco.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 C02
- Issued
- Apr 23, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: (a) at 7801 Westheimer Rd., Houston, TX, Fish and the Knife, employees were exposed to fall hazards when using a 6 foot, 4 inch, walk through, fabricated frame scaffold with only one of two "X" braces.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 A02 II I
- Issued
- Apr 23, 2013
- Penalty
- Initial $400 · Current $240 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage: (a) at 7801 Westhiemer Road, Houston, TX, in the Fish and the Knife parking lot, employees were exposed to electrical hazards when using extension cords, to power their drill, damaged by vehicular traffic.
Recent events (2)
- — I (O) $240
- — Z (O) $400
More inspections in this industry (NAICS 238140)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339019226.