FARMINGTON, MO —
OSHA Inspection: THE MOLDING COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of THE MOLDING COMPANY in 1601 AIR PARK DRIVE, FARMINGTON, MO 63640 (NAICS 326199). OSHA activity number 339019887.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE MOLDING COMPANY
- Site address
- 1601 AIR PARK DRIVE
- City
- FARMINGTON
- State
- MO
- ZIP
- 63640
- Mailing
- 1601 AIR PARK DRIVE, FARMINGTON, MO 63640
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 69
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.178 P01
- Issued
- May 22, 2013
- Abate by
- Jun 18, 2013
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): JOBSITE: 1601 Air Park Drive, Farmington, MO 63640, at this location in the receiving area a forklift operator was observed operating a Nissan 50 Forklift, Model: MCP1F2A25LV, UNIT#: 6262/FPS001. A safety check was performed and revealed: 1) Defective emergency brakes 2) The rear driver side tire had multiple cuts of two (2) inches or more
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1910.212 A01
- Issued
- May 22, 2013
- Abate by
- Jun 18, 2013
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, flying chips and sparks: JOBSITE: 1601 Air Park Drive, Farmington, MO 63640, at this facility and in general plant maintenance, Bridgeport Drill Press Unit# Z601, Model: 707038, S/N: J106961 and Dayton Drill Press Unit# 0004, Model: 3Z919C, S/N: 200003 were missing chuck guards.
Recent events (2)
- — I (O) $0
- — Z (S) $3500
1910.334 A02 II
- Issued
- May 22, 2013
- Abate by
- Jun 18, 2013
- Penalty
- Initial $10,780 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made: JOBSITE: 1601 Air Park Drive, Farmington, MO 63640, at this location in the mixing area a portable fan, Big Country Breeze, BCB-20F-DDF, was being used with a defective electrical cord. A visual inspection revealed a missing ground pin. The Molding Company dba Forte Product Solutions was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.334(a)(2)(ii), which was contained in OSHA inspection number 313637050, citation number 3, item number 1, issued on September 2, 2009 and was affirmed as a final order on September 28, 2009, with respect to a workplace located at 1601 Air Park Drive, Farmington, MO 63640.
Recent events (2)
- — I (S) $3000
- — Z (R) $10780
1910.147 C06 I
- Issued
- May 22, 2013
- Abate by
- Jun 18, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: JOBSITE: 1601 Air Park Drive, Farmington, MO 63640, at this location the employer failed to conduct a periodic inspection of the energy control procedures since March 2012.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at The Molding Company