On , OSHA opened a complaint health inspection of TIM HORTONS in 290 NORTH STREET, HOULTON, ME 04730 (NAICS 722514). OSHA activity number 339020273.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch TIM Hortons — free Get an email when a new federal OSHA severe-injury report for TIM Hortons is published. One employer, no account, unsubscribe in one click.
Establishment
TIM HORTONS
Site address
290 NORTH STREET
City
HOULTON
State
ME
ZIP
04730
Mailing
290 NORTH STREET, HOULTON, ME 04730
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722514
Employees
25
Ownership type
A

6 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 25 exposed
Issued
May 1, 2013
Abate by
May 13, 2013
Penalty
Initial $1,600 · Current $1,280 Reduced
29 CFR 1910.101(b): "Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6.  Soda Mixing Room - The spare CO2 cylinder is not secured in an upright manner as required in paragraph 3.5.8 of Pamphlet P-1.
Recent events (2)
  • — I (S) $1280
  • — Z (S) $1600

1910.303 G01 I A

Serious Gravity 1 1 instance 25 exposed
Issued
May 1, 2013
Abate by
May 9, 2013
Penalty
Initial $1,200 · Current $960 Reduced
29 CFR 1910.303(g)(1)(i)(A): The depth of the working space in the direction of access to live parts may not be less than indicated in Table S-1. Distances shall be measured from the live parts if they are exposed or from the enclosure front or opening if they are enclosed;  Rear Storage Room-  Metal racks were within the three foot exclusion distance of the front of the circuit breaker panels.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1200

1910.1200 E01

Serious Gravity 1 1 instance 25 exposed
Issued
May 1, 2013
Abate by
May 20, 2013
Penalty
Initial $1,200 · Current $960 Reduced
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following:  Facility-wide-   The employer did not develop or implement a written hazard communications program as required.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1200

1910.37 B06

Other-than-serious 1 instance 25 exposed
Issued
May 1, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign must be illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. Self-luminous or electroluminescent signs that have a minimum luminance surface value of at least .06 footlamberts (0.21 cd/m2) are permitted.  Rear Exit Door - The EXIT sign did not illuminate, as designed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.151 C

Other-than-serious 1 instance 25 exposed
Issued
May 1, 2013
Abate by
May 13, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.  [63 FR 33450, June 18, 1998]  Facility - The available eyewash equipment is not capable of delivering flushing fluid to both eyes at least 1.5 liters   (0.4 gallons) per minute for 15 minutes.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 3 instances 25 exposed
Issued
May 1, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.  Facility-Wide-   The portable fire extinguishers in the facility are not visually inspected monthly to ensure servicability.
Recent events (2)
  • — I (O) $0