MILWAUKEE, WI ·
OSHA Inspection: ADM GRAIN RIVER SYSTEM, INC. A SUBSIDIARY OF ARCHER-DANIELS-MIDLAND COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADM GRAIN RIVER SYSTEM, INC. A SUBSIDIARY OF ARCHER-DANIELS-MIDLAND COMPANY in 335 S. EMMBER LANE, MILWAUKEE, WI 53203 (NAICS 493130). OSHA activity number 339020711.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 335 S. EMMBER LANE
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53203
- Mailing
- W13136 COUNTY RD. KK, RIPON, WI 54971
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493130
- Employees
- 3
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.24 F
- Issued
- Jul 26, 2013
- Abate by
- Aug 21, 2013
- Penalty
- Initial $3,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs: (a) The stairs leading to the office from the platform had the tread widths which were not uniform exposing employees to trip hazards.
Recent events (2)
- · I (O) $0
- · Z (S) $3000
1910.137 B02 II
- Issued
- Jul 26, 2013
- Abate by
- Aug 21, 2013
- Penalty
- Initial $4,000 · Current $4,000
General-duty citation text
29 CFR 1910.137(b)(2)(ii): Insulating equipment was not inspected for damage before each day's use and immediately following any incident that could reasonably be suspected of having caused damage: (a) Approximately 3 weeks prior to the inspection, the Salisbury electrical gloves were not tested prior to use when changing out fuses. This exposed employees to electrical shock hazards.
Recent events (2)
- · I (S) $4000
- · Z (S) $4000
1910.137 B02 VIII
- Issued
- Jul 26, 2013
- Abate by
- Aug 21, 2013
- Penalty
- Initial $4,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.137(b)(2)(viii): Electrical protective equipment was not subjected to periodic electrical tests in accordance with Tables I-5 and I-6: (a) The Salisbury Class 0 rubber electrical gloves was not tested at least every 6 months. The last test was conducted in November 2011. This exposed employees to electrical shock hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $4000
1910.272 J01
- Issued
- Jul 26, 2013
- Abate by
- Oct 15, 2013
- Penalty
- Initial $7,000 · Current $4,900 Reduced
General-duty citation text
29 CFR 1910.272(j)(1): The employer did not develop and implement a written housekeeping program that established the frequency and the method(s) determined best to reduce accumulations of fugitive grain dust on ledges, floors, equipment, and other expose: (a) On the 5th floor, by the shaker screener cleaning was not performed as required by the implementation of a housekeeping program, exposing employees to combustible dust hazards.
Recent events (2)
- · I (S) $4900
- · Z (S) $7000
1910.146 E06
- Issued
- Jul 26, 2013
- Abate by
- Aug 21, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(e)(6): The employer did not retain each canceled entry permit for at least one year to facilitate the review of the permit-required confined space program required by 29 CFR 1910.146(d)(14): (a) Permit-required confined space permits were not maintained for at least a year after entering space such as but not limited to: dust collection system.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.147 C06 I
- Issued
- Jul 26, 2013
- Abate by
- Sep 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) The employer did not review all energy control procedures to verify or ensure their accuracy.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 493130)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339020711.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.