Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NAUGATUCK STAIR COMPANY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NAUGATUCK STAIR COMPANY, INC. in 51 ELM STREET PO BOX 384, NAUGATUCK, CT 06770 (NAICS 321918). OSHA activity number 339021453.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Naugatuck Stair Company, INC. — free Get an email when a new federal OSHA severe-injury report for Naugatuck Stair Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
51 ELM STREET PO BOX 384
City
NAUGATUCK
State
CT
ZIP
06770
Mailing
51 ELM STREET PO BOX 384, NAUGATUCK, CT 06770
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
10
Ownership type
A

13 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 2 instances 6 exposed
Issued
Sep 6, 2013
Abate by
Oct 24, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition.     WORKSHOP:       1. Combustible wood dust was allowed to accumulate on the floor in and around the RUWO Stringer machine, air hose, back of the machines, electrical wires, beams, and work table. The dust layers were allowed to accumulate to sufficient depth and spread over a sufficient surface area to create a fire/explosion hazard.       2. Combustible wood dust was allowed to accumulate on the floor in and around the Rockwell Radial Arm saw, saw, work table, beams, electric motor. The dust layers were allowed to accumulate to a sufficient depth and spread over a sufficient surface area to create a fire/explosion hazard.     3.  Combustible wood dust was allowed to accumulate on the tops of the walls, beams, floor joists, light fixtures, and piping.  The dust layers were allowed to accumulate to sufficient depth and spread over a sufficient surface area to create a fire/explosion hazard.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.147 C01

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 6, 2013
Abate by
Sep 16, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    WORKSHOP:   The employer had not established and implemented a site specific hazardous energy control lo/to program consisting of machine specific step-by-step written procedures and employee training for the employees during servicing and maintenance of equipment, such as (but not limited to) stringer machine.    ABATED DURING THE INSPECTION.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 6, 2013
Abate by
Nov 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.     WORKSHOP:  The employer had not established and implemented hazardous energy control procedures in machine specific for the employee during servicing and maintenance of equipment, such as (but not limited to) the stringer machine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 6, 2013
Abate by
Nov 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:    WORKSHOP:  The employees, as affected and/or other typeswere not provided with training and information in the controlling of potentially hazardous and unexpected releases of revised energy sources (lockout/tagout) during servicing and maintenance of equipment, such as (but not limited to) the stringer machine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 H01

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 6, 2013
Abate by
Sep 16, 2013
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade shall be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed.    WORKSHOP:  The sides of the lower portion of the blade of the Rockwell radial arm saw were not guarded by an appropriate type of guard/device.       ABATED DURING THE INSPECTION.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.213 H02

Serious Gravity 5 2 instances 5 exposed
Issued
Sep 6, 2013
Abate by
Sep 16, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.213(h)(2): Each radial saw used for ripping shall be provided with nonkickback fingers or dogs located on both sides of the saw so as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator. They shall be designed to provide adequate holding power for all the thicknesses of material being cut.  WORKSHOP:  The following radial arm saws were not equipped with nonkickback fingers or dogs:      1.  DeWalt. 2.  Rockwell.  ABATED DURING THE INSPECTION.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 H03

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 6, 2013
Abate by
Sep 16, 2013
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.213(h)(3): An adjustable stop shall be provided to prevent the forward travel of the blade beyond the position necessary to complete the cut in repetitive operations.    WORKSHOP:  The Rockwell radial arm saw was not equipped with an adjustable stop.     ABATED DURING THE INSPECTION.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1910.213 H04

Serious 1 instance 5 exposed
Issued
Sep 6, 2013
Abate by
Sep 16, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.213(h)(4): Installation shall in such a manner that the front end of the unit will be slightly higher than the rear, so as to cause the cutting head to return gently to the starting position when released by the operator:    WORKSHOP:  The cutting head of the Rockwell radial arm did not return to the starting position automatically when released by the operator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 5 instances 5 exposed
Issued
Sep 6, 2013
Abate by
Oct 24, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.     WORKSHOP:  Non-classified electrical equipment, such as (but not limited to) non-gasket control boxes, extension cords, electric motors and switches rated at 120 V/60 HZ alternating current were installed and used throughout the work area where combustible and explosive wood dust was not only generated, but also accumulated.      The extension cords attached to the Delta 50-760 dust collectors for the woodworking machinery were not approved for nor safe for use in a Class II, Division 2 hazardous location.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.304 G06 VI

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 6, 2013
Abate by
Sep 16, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.304(g)(6)(vi): Exposed noncurrent carrying metal parts of cord-and-plug-connected equipment that may become energized shall be grounded:    WORKSHOP:  The attachment plug of the flexible power cord of the Delta dust collection unit was missing a grounding pin.      ABATED DURING THE INSPECTION.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.305 G01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 6, 2013
Abate by
Sep 16, 2013
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.305(g)(1)(i): Flexible cords and cables shall be approved for conditions of use and location:    WORKSHOP:  The orange flexible extension cord, used to power a portable hand sander was concealed behind several pieces of wooden boards stored in behind the Stringer machine and was exposed to physical damage.      ABATED DURING THE INSPECTION.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1910.38 B

Other-than-serious 1 instance 6 exposed
Issued
Sep 6, 2013
Abate by
Oct 24, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.38(b): Written and oral emergency action plans. An emergency action plan must be in writing, kept in the workplace, and available to employees for review. However, an employer with 10 or fewer employees may communicate the plan orally to employees.  WORKSHOP:  The employer had not established and implemented a written emergency evacuation plan for the employees.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.145 C02 I

Other-than-serious 1 instance 5 exposed
Issued
Sep 6, 2013
Abate by
Sep 16, 2013
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.145(c)(2)(i): Caution signs shall be used only to warn against potential hazards or to caution against unsafe practices.    WORKSHOP:  Caution signs were not placed on the portable Delta 50-700 dust collectors to warn employees against potential hazards while handling potentially explosive wood dust.     ABATED DURING THE INSPECTION.
Recent events (2)
  • — I (O) $0
  • — Z (S) $1600

View Naugatuck Stair Company, INC.'s full OSHA safety record →