NAUGATUCK, CT —
OSHA Inspection: NAUGATUCK STAIR COMPANY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NAUGATUCK STAIR COMPANY, INC. in 51 ELM STREET PO BOX 384, NAUGATUCK, CT 06770 (NAICS 321918). OSHA activity number 339021453.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NAUGATUCK STAIR COMPANY, INC.
- Site address
- 51 ELM STREET PO BOX 384
- City
- NAUGATUCK
- State
- CT
- ZIP
- 06770
- Mailing
- 51 ELM STREET PO BOX 384, NAUGATUCK, CT 06770
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321918
- Employees
- 10
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.22 A01
- Issued
- Sep 6, 2013
- Abate by
- Oct 24, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition. WORKSHOP: 1. Combustible wood dust was allowed to accumulate on the floor in and around the RUWO Stringer machine, air hose, back of the machines, electrical wires, beams, and work table. The dust layers were allowed to accumulate to sufficient depth and spread over a sufficient surface area to create a fire/explosion hazard. 2. Combustible wood dust was allowed to accumulate on the floor in and around the Rockwell Radial Arm saw, saw, work table, beams, electric motor. The dust layers were allowed to accumulate to a sufficient depth and spread over a sufficient surface area to create a fire/explosion hazard. 3. Combustible wood dust was allowed to accumulate on the tops of the walls, beams, floor joists, light fixtures, and piping. The dust layers were allowed to accumulate to sufficient depth and spread over a sufficient surface area to create a fire/explosion hazard.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.147 C01
- Issued
- Sep 6, 2013
- Abate by
- Sep 16, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. WORKSHOP: The employer had not established and implemented a site specific hazardous energy control lo/to program consisting of machine specific step-by-step written procedures and employee training for the employees during servicing and maintenance of equipment, such as (but not limited to) stringer machine. ABATED DURING THE INSPECTION.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.147 C04 I
- Issued
- Sep 6, 2013
- Abate by
- Nov 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. WORKSHOP: The employer had not established and implemented hazardous energy control procedures in machine specific for the employee during servicing and maintenance of equipment, such as (but not limited to) the stringer machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Sep 6, 2013
- Abate by
- Nov 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following: WORKSHOP: The employees, as affected and/or other typeswere not provided with training and information in the controlling of potentially hazardous and unexpected releases of revised energy sources (lockout/tagout) during servicing and maintenance of equipment, such as (but not limited to) the stringer machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 H01
- Issued
- Sep 6, 2013
- Abate by
- Sep 16, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade shall be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed. WORKSHOP: The sides of the lower portion of the blade of the Rockwell radial arm saw were not guarded by an appropriate type of guard/device. ABATED DURING THE INSPECTION.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.213 H02
- Issued
- Sep 6, 2013
- Abate by
- Sep 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(h)(2): Each radial saw used for ripping shall be provided with nonkickback fingers or dogs located on both sides of the saw so as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator. They shall be designed to provide adequate holding power for all the thicknesses of material being cut. WORKSHOP: The following radial arm saws were not equipped with nonkickback fingers or dogs: 1. DeWalt. 2. Rockwell. ABATED DURING THE INSPECTION.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 H03
- Issued
- Sep 6, 2013
- Abate by
- Sep 16, 2013
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.213(h)(3): An adjustable stop shall be provided to prevent the forward travel of the blade beyond the position necessary to complete the cut in repetitive operations. WORKSHOP: The Rockwell radial arm saw was not equipped with an adjustable stop. ABATED DURING THE INSPECTION.
Recent events (2)
- — I (S) $0
- — Z (S) $1600
1910.213 H04
- Issued
- Sep 6, 2013
- Abate by
- Sep 16, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(h)(4): Installation shall in such a manner that the front end of the unit will be slightly higher than the rear, so as to cause the cutting head to return gently to the starting position when released by the operator: WORKSHOP: The cutting head of the Rockwell radial arm did not return to the starting position automatically when released by the operator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Sep 6, 2013
- Abate by
- Oct 24, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. WORKSHOP: Non-classified electrical equipment, such as (but not limited to) non-gasket control boxes, extension cords, electric motors and switches rated at 120 V/60 HZ alternating current were installed and used throughout the work area where combustible and explosive wood dust was not only generated, but also accumulated. The extension cords attached to the Delta 50-760 dust collectors for the woodworking machinery were not approved for nor safe for use in a Class II, Division 2 hazardous location.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.304 G06 VI
- Issued
- Sep 6, 2013
- Abate by
- Sep 16, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.304(g)(6)(vi): Exposed noncurrent carrying metal parts of cord-and-plug-connected equipment that may become energized shall be grounded: WORKSHOP: The attachment plug of the flexible power cord of the Delta dust collection unit was missing a grounding pin. ABATED DURING THE INSPECTION.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.305 G01 I
- Issued
- Sep 6, 2013
- Abate by
- Sep 16, 2013
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(i): Flexible cords and cables shall be approved for conditions of use and location: WORKSHOP: The orange flexible extension cord, used to power a portable hand sander was concealed behind several pieces of wooden boards stored in behind the Stringer machine and was exposed to physical damage. ABATED DURING THE INSPECTION.
Recent events (2)
- — I (S) $0
- — Z (S) $1600
1910.38 B
- Issued
- Sep 6, 2013
- Abate by
- Oct 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.38(b): Written and oral emergency action plans. An emergency action plan must be in writing, kept in the workplace, and available to employees for review. However, an employer with 10 or fewer employees may communicate the plan orally to employees. WORKSHOP: The employer had not established and implemented a written emergency evacuation plan for the employees.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.145 C02 I
- Issued
- Sep 6, 2013
- Abate by
- Sep 16, 2013
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.145(c)(2)(i): Caution signs shall be used only to warn against potential hazards or to caution against unsafe practices. WORKSHOP: Caution signs were not placed on the portable Delta 50-700 dust collectors to warn employees against potential hazards while handling potentially explosive wood dust. ABATED DURING THE INSPECTION.
Recent events (2)
- — I (O) $0
- — Z (S) $1600
More inspections at Naugatuck Stair Company, INC.
View Naugatuck Stair Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321918)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339021453.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.