Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: USDA ANIMAL & PLANT HEALTH INSPECTION SERVICE; PPQ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of USDA ANIMAL & PLANT HEALTH INSPECTION SERVICE; PPQ in 2281 W. HEYREND WAY, IDAHO FALLS, ID 83402 (NAICS 926140). OSHA activity number 339021909.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Usda Animal & Plant Health Inspection Service; PPQ — free Get an email when a new federal OSHA severe-injury report for Usda Animal & Plant Health Inspection Service; PPQ is published. One employer, no account, unsubscribe in one click.
Site address
2281 W. HEYREND WAY
City
IDAHO FALLS
State
ID
ZIP
83402
Mailing
2281 W. HEYREND WAY, IDAHO FALLS, ID 83402
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
926140
Employees
60
Ownership type
D

6 citations on file for this inspection.

1910.151 C

Serious Gravity 5 2 instances 60 exposed
Issued
Jul 16, 2013
Abate by
Aug 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate use:    a.)  Soil Lab:  A readily available eyewash facility was not provided.  Employees were exposed to chemical disinfectant detergent cleaner with pH up to 12.0.    b.)  Warehouse:  A readily available eyewash facility was not provided.  Employees were exposed to concentrated bleach with pH up to 13.5.    Note: Abatement certification is required for this item
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 16, 2013
Abate by
Aug 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a.)  Warehouse, Fleet Shop:  Compressed air at over 100 p.s.i. was used through an air nozzle to blow off metal shavings of the work bench and to clean equipment.    Note: Abatement certification is required for this item
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 16, 2013
Abate by
Aug 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.253(e)(1): Welding and cutting equipment was not installed and used as recommended by the manufacturer:    a.)  Warehouse, Fleet Shop:  The gauge, to the argon gas regulator, had view glass missing.     Note: Abatement certification is required for this item
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 60 exposed
Issued
Jul 16, 2013
Abate by
Aug 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):  Flexible cords and cables were used as a substitute for the fixed wiring of a structure:    a.)  North East of Warehouse:  Three extension cord sets and a triple tap power cable cord were connected to a permanent outlet to energize equipment and appliances.  Additional permanent electrical outlets were not provided.    Note: Abatement certification is required for this item
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 II

Deleted Serious Gravity 5 1 instance 60 exposed
Issued
Jul 16, 2013
Abate by
Aug 30, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(ii):  In locations where electric equipment is likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage:    a.)  North Side of the Building:  On or about April 24, 2013, and at times prior thereto, the 12,470-Volt electrical transformer adjacent to the parking lot was not provided with bollards to protect from vehicles.    Among other methods, one feasible and acceptable abatement method of providing mechanical protection is to strategically place bollards around the transformer.  This practice provides a degree of protection from vehicles in accordance with the National Electrical Code Handbook-2011, Article 450.8(A) Mechanical Protection for Guarding of Transformers.      Note: Abatement certification is required for this item
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Serious Gravity 5 1 instance 60 exposed
Issued
Jul 16, 2013
Abate by
Aug 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5):  Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    a.)  North East Corner of Warehouse:  A wall-mounted receptacle outlet was false-grounded exposing employees to the hazard of electric shock.    Note: Abatement certification is required for this item
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Usda Animal & Plant Health Inspection Service; PPQ's full OSHA safety record →