OSHA Inspection: USDA ANIMAL & PLANT HEALTH INSPECTION SERVICE; PPQ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of USDA ANIMAL & PLANT HEALTH INSPECTION SERVICE; PPQ in 2281 W. HEYREND WAY, IDAHO FALLS, ID 83402 (NAICS 926140). OSHA activity number 339021909.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- USDA ANIMAL & PLANT HEALTH INSPECTION SERVICE; PPQ
- Site address
- 2281 W. HEYREND WAY
- City
- IDAHO FALLS
- State
- ID
- ZIP
- 83402
- Mailing
- 2281 W. HEYREND WAY, IDAHO FALLS, ID 83402
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 926140
- Employees
- 60
- Ownership type
- D
Citations
6 citations on file for this inspection.
1910.151 C
- Issued
- Jul 16, 2013
- Abate by
- Aug 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate use: a.) Soil Lab: A readily available eyewash facility was not provided. Employees were exposed to chemical disinfectant detergent cleaner with pH up to 12.0. b.) Warehouse: A readily available eyewash facility was not provided. Employees were exposed to concentrated bleach with pH up to 13.5. Note: Abatement certification is required for this item
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Jul 16, 2013
- Abate by
- Aug 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a.) Warehouse, Fleet Shop: Compressed air at over 100 p.s.i. was used through an air nozzle to blow off metal shavings of the work bench and to clean equipment. Note: Abatement certification is required for this item
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 E01
- Issued
- Jul 16, 2013
- Abate by
- Aug 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(e)(1): Welding and cutting equipment was not installed and used as recommended by the manufacturer: a.) Warehouse, Fleet Shop: The gauge, to the argon gas regulator, had view glass missing. Note: Abatement certification is required for this item
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Jul 16, 2013
- Abate by
- Aug 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: a.) North East of Warehouse: Three extension cord sets and a triple tap power cable cord were connected to a permanent outlet to energize equipment and appliances. Additional permanent electrical outlets were not provided. Note: Abatement certification is required for this item
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 II
- Issued
- Jul 16, 2013
- Abate by
- Aug 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment is likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage: a.) North Side of the Building: On or about April 24, 2013, and at times prior thereto, the 12,470-Volt electrical transformer adjacent to the parking lot was not provided with bollards to protect from vehicles. Among other methods, one feasible and acceptable abatement method of providing mechanical protection is to strategically place bollards around the transformer. This practice provides a degree of protection from vehicles in accordance with the National Electrical Code Handbook-2011, Article 450.8(A) Mechanical Protection for Guarding of Transformers. Note: Abatement certification is required for this item
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 G05
- Issued
- Jul 16, 2013
- Abate by
- Aug 9, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a.) North East Corner of Warehouse: A wall-mounted receptacle outlet was false-grounded exposing employees to the hazard of electric shock. Note: Abatement certification is required for this item
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Usda Animal & Plant Health Inspection Service; PPQ
View Usda Animal & Plant Health Inspection Service; PPQ's full OSHA safety record →
More inspections in this industry (NAICS 926140)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339021909.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.