Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: ASSOCIATED ENTERPRISES

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ASSOCIATED ENTERPRISES in 1382 WEST JACKSON STREET, PAINESVILLE, OH 44077 (NAICS 334417). OSHA activity number 339022014.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Associated Enterprises for free Get an email when a new federal OSHA severe-injury report for Associated Enterprises is published. One employer, no account, unsubscribe in one click.
Site address
1382 WEST JACKSON STREET
City
PAINESVILLE
State
OH
ZIP
44077
Mailing
1382 WEST JACKSON STREET, PAINESVILLE, OH 44077
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334417
Employees
150
Ownership type
Private (A)

9 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
May 28, 2013
Abate by
Jun 30, 2013
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    On or before 4/24/13, the employer did not establish a program to protect employees involved with servicing and maintenance of machines and equpment from the unexpected energizing, start up, or release of stored energy.  Energy sources included, but are not limited to, electrical, pneumatic, hydraulic, etc.  The company maintains and services equipment such as, but not limited to, mechanical power presses, injection molding presses, CNC machines, guillotine cutters, etc.
Recent events (2)
  • · I (S) $2700
  • · Z (S) $4500

1910.157 G02

Serious Gravity 1 1 instance 1 exposed
Issued
May 28, 2013
Abate by
Jun 30, 2013
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.157(g)(2):  The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:       The employer did not train employees on the use of portable fire extinguishers for those employees expected to fight incipient stage fires.       NOTE:  The employer may exercise one of the following options:       1)      Provide portable fire extinguishers as specified in 29 CFR 1910.157(c)(1), meet the distribution requirements per 29 CFR 1910.157(d) (75 to the nearest extinguisher for Class A fires and 50 to the nearest extinguisher for Class B fires), and provide training and education for all employees in the use of such equipment and the hazards associated with incipient stage fire fighting as required in 29 CFR 1910.157(g).  The other sections of 29 CFR 1910.157 also apply.       2)      Provide extinguishers as specified in 29 CFR 1910.157(c) (1), designate certain employees to be the only employees authorized to use such equipment and require all other employees to immediately evacuate upon the sounding of the fire alarm, establish this in writing in an emergency action plan as outlined in 29 CFR 1910.38(c) and train/educate designated employees per 1910.157(g).  Utilizing this option exempts the employer from distribution requirements of 29 CFR 1910.157(d).       3)        Establish a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal.  This policy includes an emergency action plan and a fire prevention plan as specified in 29 CFR 1910.38(a) and (b).  Utilizing this option exempts the employer from the requirements of 1910.157 to include the need for providing portable fire equipment unless a specific standard requires that a portable fire extinguisher be provided (such as those requirements in 29 CFR 1910.106/107 relating to use/storage of flammable/combustible liquids).  If extinguishers are provided but not intended for employee use, 29 CFR 1910.157(a) and (f) are still applicable (inspection, maintenance and testing of equipment).
Recent events (2)
  • · I (S) $1620
  • · Z (S) $2700

1910.212 A01

Serious Gravity 10 6 instances 1 exposed
Issued
May 28, 2013
Abate by
Jul 15, 2013
Penalty
Initial $6,300 · Current $3,780 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by nip points  and/or points of operation:    The following equipment was not adequately guarded:    (a)  Dynamite #1 and #2 bench top mill(s) did not have any guarding;    (b)  Bostomatic CNC did not have the spindle guarded;    (c)  The seven CNC Fadal machines did not have interlocks;    (d)  The Newbury 30 injection molder machine, model 4230BRS, S/N 129180 30BS 9J;  the casting was broke for the guard which did not prevent the die from drifting down;    (e)  The two (2) air powered guillotine cutters did not have the guard secured or affixed in place;    (f)  The Arburg vertical mold press had an opening the guard which measured approximately 2 1/2 x 17 inches
Recent events (2)
  • · I (S) $3780
  • · Z (S) $6300

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
May 28, 2013
Abate by
Jun 7, 2013
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    The Craftsman bench grinder did not have the work rest properly adjusted.  The opening measured approximately 1/2 inch.
Recent events (2)
  • · I (S) $1620
  • · Z (S) $2700

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
May 28, 2013
Abate by
Jun 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  The Craftsman bench grinder had the tongue guard adjusted to approximately 1inch.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.217 C01 I

Serious Gravity 10 3 instances 1 exposed
Issued
May 28, 2013
Abate by
Jun 14, 2013
Penalty
Initial $6,300 · Current $3,780 Reduced
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es):     The following mechanical power press(es) were not adequately guarded:     (a)  Minster #8, part revolution mechanical power press, operated in continuous mode, did not have the door(s) interlocked;     (b)  Minster #4, part revolution mechanical power press, operated in continuous mode, did not have the door interlocked;     (c)  The Federal 32 #6, part revolution mechanical power press, operated in continuous mode, did not have any point of operation guarding.
Recent events (2)
  • · I (S) $3780
  • · Z (S) $6300

1910.217 D09 IV

Serious Gravity 10 3 instances 1 exposed
Issued
May 28, 2013
Abate by
Jul 15, 2013
Penalty
Initial $6,300 · Current $3,780 Reduced
29 CFR 1910.217(d)(9)(iv): Safety blocks were not used when mechanical power press die(s) were being adjusted or repaired in the press:    Safety blocks were not used on mechanical power presses when dies were being repaired or adjusted on the Minster 8, Minster 4 and Federal 32 mechanical power press.
Recent events (2)
  • · I (S) $3780
  • · Z (S) $6300

1910.303 B02

Serious Gravity 1 2 instances 1 exposed
Issued
May 28, 2013
Abate by
Jun 14, 2013
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a)  Assembly area:  A junction box was not secured.  It was lying on the ground used to power two Branson welders;    (b)  A power strip was used to power air solenoids for welders.
Recent events (2)
  • · I (S) $1620
  • · Z (S) $2700

1910.305 G01 III

Serious Gravity 1 1 instance 1 exposed
Issued
May 28, 2013
Abate by
Jun 7, 2013
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.305(g)(1)(iii): Flexible cords and cables were used for purposes prohibited by subparagraphs (A) through (E) of this paragraph:    An extension cord was being used in lieu of fixed wiring to power a computer.  The extension cord was coming through the ceiling.
Recent events (2)
  • · I (S) $1620
  • · Z (S) $2700

View Associated Enterprises's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339022014.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.