DORSEY, IL —
OSHA Inspection: MCCANN CONCRETE PRODUCTS INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MCCANN CONCRETE PRODUCTS INC in 8709 N STATE ROUTE 159, DORSEY, IL 62021 (NAICS 327390). OSHA activity number 339022162.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MCCANN CONCRETE PRODUCTS INC
- Site address
- 8709 N STATE ROUTE 159
- City
- DORSEY
- State
- IL
- ZIP
- 62021
- Mailing
- 8709 N STATE ROUTE 159, DORSEY, IL 62021
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327390
- Employees
- 32
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.37 B02
- Issued
- Oct 15, 2013
- Abate by
- Oct 21, 2013
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": Employees were exposed to fire and burn hazards and the exit door on the rear of the shop was not clearly visible and marked by a sign reading "Exit".
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1910.334 A02 II
- Issued
- Oct 15, 2013
- Abate by
- Oct 21, 2013
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: Main Shop Floor- Employees were exposed to electrical shock and burns when working with extension cords that were not removed from service when the cords were damaged on both the outer and the inner coverings.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1910.22 D01
- Issued
- Oct 15, 2013
- Abate by
- Nov 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate: Employees were exposed to structural collapse due to a loft over the employees bathroom and break room was not marked to show the loads approved by a building official.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Mccann Concrete Products INC
View Mccann Concrete Products INC's full OSHA safety record →
More inspections in this industry (NAICS 327390)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339022162.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.