CHEEKTOWAGA, NY —
OSHA Inspection: A BEST ROOFING & SIDING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of A BEST ROOFING & SIDING, INC. in 3748-3750 HARLEM ROAD, CHEEKTOWAGA, NY 14215 (NAICS 238160). OSHA activity number 339025355.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A BEST ROOFING & SIDING, INC.
- Site address
- 3748-3750 HARLEM ROAD
- City
- CHEEKTOWAGA
- State
- NY
- ZIP
- 14215
- Mailing
- 7 PAYNE AVENUE, NORTH TONAWANDA, NY 14120
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.21 B02
- Issued
- May 13, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) On or about 04/25/13, on commercial roofing construction site, 3748-3750 Harlem Rd., Cheektowaga, NY: An employee who was exposed to fall hazards from the roof, falls from ladders, and electrical hazards while using hand-held portable electric tools and extension cords, was not trained in the recognition and avoidance of these hazards and the applicable OSHA regulations to control or eliminate these hazards. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.404 B01 I
- Issued
- May 13, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $1,360 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) On or about 04/25/13, on commercial roofing construction site, 3748-3750 Harlem Rd., Cheektowaga, NY: Employees used a DeWalt Model DW235G Screwgun to install wooden boards on the parapet walls. The screwgun was connected to 120-volt ac power via a series of extension cords, the first of which was plugged into a wall receptacle in the basement. No GFCI or assured equipment grounding program was being used. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $1360
1926.404 F06
- Issued
- May 13, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $1,360 · Current $800 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about 04/25/13, on commercial roofing construction site, 3748-3750 Harlem Rd., Cheektowaga, NY: Employees used a DeWalt Model DW235G Screwgun to install wooden boards on the parapet walls. The screwgun was connected to 120-volt ac power via a series of extension cords, the first of which was plugged into a wall receptacle in the basement. The grounding prong on the plug of the screwgun was missing. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $800
- — Z (S) $1360
1926.405 A02 II J
- Issued
- May 13, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances were not of the three-wire type: a) On or about 04/25/13, on commercial roofing construction site, 3748-3750 Harlem Rd., Cheektowaga, NY: Employees used a DeWalt Model DW235G Screwgun to install wooden boards on the parapet walls. The screwgun was connected to 120-volt ac power via a series of extension cords, the first of which was plugged into a wall receptacle in the basement. The last extension cord in the series was only a 2-wire type. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B10
- Issued
- May 13, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $1,360 · Current $800 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) On or about 04/25/13, on commercial roofing construction site, 3748-3750 Harlem Rd., Cheektowaga, NY: Employees were exposed to a potential fall of approx. 14 ft. while on a flat roof doing roofing work that included putting metal capping on the roof edges. No fall protection system was utilized. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $800
- — Z (S) $1360
1926.1053 B01
- Issued
- May 13, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $1,020 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders' length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 04/25/13, on commercial roofing construction site, 3748-3750 Harlem Rd., Cheektowaga, NY: Employees were exposed to a fall of approx. 14 ft. when an extension ladder was used to access the roof from the ground. The siderails of the ladder only extended approx. 28 inches above the roof. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $1020
1926.405 A02 II I
- Issued
- May 13, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables shall be protected from damage. Sharp corners and projections shall be avoided. Flexible cords and cables may pass through doorways or other pinch points, if protection is provided to avoid damage. a) On or about 04/25/13, on commercial roofing construction site, 3748-3750 Harlem Rd., Cheektowaga, NY: Employees used a DeWalt Model DW235G Screwgun to install wooden boards on the parapet walls. The screwgun was connected to 120-volt ac power via a series of extension cords. The second last extension cord in the series ran under the outside door to the basement. The door was closed onto the cord pinching the outer sheath of the cord. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at A Best Roofing & Siding, INC.
View A Best Roofing & Siding, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339025355.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.