Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CUSTOM ELECTRIC INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CUSTOM ELECTRIC INC. in 52 MAIN STREET, MANCHESTER, CT 06042 (NAICS 238210). OSHA activity number 339025660.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Custom Electric INC. — free Get an email when a new federal OSHA severe-injury report for Custom Electric INC. is published. One employer, no account, unsubscribe in one click.
Site address
52 MAIN STREET
City
MANCHESTER
State
CT
ZIP
06042
Mailing
52 MAIN STREET, MANCHESTER, CT 06042
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
1
Ownership type
A

5 citations on file for this inspection.

1926.405 A02 II I

Other-than-serious 1 instance 2 exposed
Issued
May 29, 2013
Abate by
Jun 4, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage.    a)  52 Main St., Manchester, CT. Job Site - On or about 4-25-13 - Flexible cord that was run through a metal pipe was not protected from abrasion damage at the end of the pipe.
Recent events (3)
  • — F (O) $1600
  • — C (S) $1600
  • — Z (S) $1600

1926.405 E01

Other-than-serious 1 instance 4 exposed
Issued
May 29, 2013
Abate by
Jun 4, 2013
Penalty
Initial $1,360 · Current $1,360
29 CFR 1926.405(e)(1): In wet locations, cabinets, cutout boxes, fittings, boxes and panelboard enclosures were not weatherproof:    a)  52 Main Street, Manchester, CT. Job Site - On or about 4-25-13 - Employees were exposed to shock and burn hazards from 4-way metal receptacle box that was not weatherproof and installed outside for temporary power suppy.
Recent events (3)
  • — F (O) $1360
  • — C (S) $1360
  • — Z (S) $1360

1926.405 G02 III

Other-than-serious 1 instance 2 exposed
Issued
May 29, 2013
Abate by
Jun 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap:    a)  52 Main Street, Manchester, CT. Job Site - On or about 4-25-13 - Employees were exposed to electrical shock and burn hazards from a flexible cable that was spliced together to connect the 4-way receptacle box for temporary outside power.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1926.405 G02 IV

Other-than-serious 1 instance 2 exposed
Issued
May 29, 2013
Abate by
Jun 4, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:    a)  52 Main Street, Manchester, CT. Job Site - On or about 4-25-13 - Employees were exposed to electrical shock and burn hazards from flexilbe cord was connected to the 4-way receptacle box with wire nut connections, no strain relief was provided at the splice.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1926.502 D16 III

Serious Gravity 5 1 instance 2 exposed
Issued
May 29, 2013
Abate by
Jun 4, 2013
Penalty
Initial $1,700 · Current $1,700
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:    a)  52 Main Street, Manchester, CT. Job Site - On or about 4-25-13 - Employees were exposed to fall hazard of 6 to 16 feet to lower levels by using shock absorbing lanyards while in a JLG aerial lift cleaning windows on the building.
Recent events (3)
  • — F (S) $1700
  • — C (S) $1700
  • — Z (S) $1700

View Custom Electric INC.'s full OSHA safety record →