MOUNDS, IL ·
OSHA Inspection: UTLX
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of UTLX in 200 INDUSTRIAL PARK ROAD, MOUNDS, IL 62964 (NAICS 488210). OSHA activity number 339026742.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UTLX
- Site address
- 200 INDUSTRIAL PARK ROAD
- City
- MOUNDS
- State
- IL
- ZIP
- 62964
- Mailing
- 200 INDUSTRIAL PARK ROAD, MOUNDS, IL 62964
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488210
- Employees
- 4
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.101 B
- Issued
- Jul 15, 2013
- Penalty
- Initial $3,060 · Current $2,155 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: a) East Building, Northeast section, a compressed Carbon Dioxide gas cylinder was free standing; it was not properly supported by a stand or by being chained to a support or wall, to prevent it from being knocked over.
Recent events (2)
- · I (O) $2155
- · Z (S) $3060
1910.305 B01 I
- Issued
- Jul 15, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $2,295 · Current $1,600 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering boxes, cabinets, or fittings were not protected from abrasions: a) East Building, Northeast section, north wall, the conduit was pulled out of the light switch, 110 volts. This allowed the electrical wiring to be exposed to abrasions that could result in employees being exposed to electrical hazards.
Recent events (2)
- · I (O) $1600
- · Z (S) $2295
1910.305 B01 II
- Issued
- Jul 15, 2013
- Abate by
- Aug 8, 2013
- Penalty
- Initial $2,295 · Current $1,600 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) East Building, Northeast section, north wall, employees were exposed to electrical hazards, due to a main electrical panel box which had open breaker space, exposing the current carrying metal parts inside.
Recent events (2)
- · I (O) $1600
- · Z (S) $2295