Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: WEATHERFORD AEROSPACE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WEATHERFORD AEROSPACE, INC. in 1020 E. COLUMBIA ST., WEATHERFORD, TX 76086 (NAICS 336413). OSHA activity number 339026908.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Weatherford Aerospace, INC. for free Get an email when a new federal OSHA severe-injury report for Weatherford Aerospace, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1020 E. COLUMBIA ST.
City
WEATHERFORD
State
TX
ZIP
76086
Mailing
1020 E. COLUMBIA ST., WEATHERFORD, TX 76086
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336413
Employees
51
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 3 instances 15 exposed
Issued
Oct 24, 2013
Abate by
Nov 18, 2013
Penalty
Initial $3,500 · Current $1,750 Reduced
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards.  On or about April 26, 2013 and at times prior thereto, the employer did not ensure that all equipment used to aid in the process of rigging up and moving material was rated, labeled and/or inspected throughout the manufacturing facility.    Employees were exposed to struck by and crushed by hazards from the following:  a) In the G5 anodize line area, two 40 feet wide spreader bars were not rated or labeled and four Coffing 1/2 ton hoist pendent control boxes were not clearly marked to identify the functions;  b) In the G5 new line staging room, two 40 feet wide spreader bars were not rated or labeled and four Coffing 1/2 ton hoist pendent control boxes were not clearly marked to identify the functions;  c) In building 7, three spreader bars were not rated or labeled and six Coffing 1/2 ton hoist pendent control boxes were not clearly marked to identify the functions.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1910.36 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 24, 2013
Abate by
Dec 10, 2013
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.36(b)(1): At least two exits routes were not available to permit prompt evacuation of employees during an emergency:  On or about April 26, 2013 and at times prior thereto, in building 1, the tooling shop did not have two exit routes for employee emergency evacuation exposing employees to entrapment and fire hazards.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

1910.212 A03 II

Serious Gravity 5 2 instances 5 exposed
Issued
Oct 24, 2013
Abate by
Nov 18, 2013
Penalty
Initial $4,200 · Current $2,100 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s).  On or about April 26, 2103 and at times prior thereto, in building six, employees were operating Jet vertical band saws with approximately 6-8 inches of the blade exposed while cutting small metal pieces.  The employer did not ensure that the blade guards were adjusted to the height of the material being cut and employees were exposed to struck-by and amputation hazards:  a) Jet Equipment and Tools model # VBS-1610, serial # 7031891; and b) Jet Tools 14" wood/metal vertical band saw, model # J-8201K, serial #12102098
Recent events (2)
  • · I (S) $2100
  • · Z (S) $4200

1910.212 A05

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 24, 2013
Abate by
Nov 18, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:  On or about April 26, 2013, in building one, employees working in the tooling shop operated a 48 inch metal fan that was not guarded on the top and back of the fan.  Employees were exposed to the hazard of being struck by the metal fan blades.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.304 G05

Serious Gravity 5 2 instances 10 exposed
Issued
Oct 24, 2013
Abate by
Nov 18, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.304(g)(5): The paths to ground from circuits, equipment, and enclosures were not permanent, continuous, and effective.  On or about April 26, 2013 and at times prior thereto, the employer did not inspect and ensure that electrical equipment and components were used with a permanent and continuous ground.  Employees were exposed to electrical shock hazards for the following:  a) In building six, employees used a portable 36 inch floor fan that did not have a cord grounding prong. The grounding prong was broken off and missing; and    b) In building eight, employees used a Big Country round floor fan, Model # BCD-42-BDF that did not have a cord grounding pin.  The grounding pin was broken off and missing.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.305 B01 II

Serious Gravity 10 6 instances 10 exposed
Issued
Oct 24, 2013
Abate by
Nov 18, 2013
Penalty
Initial $4,900 · Current $2,200 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.    On or about April 26, 2013 and at times prior thereto, the employer did not ensure that unused openings were effectively closed to prevent employee exposure to electrocution and electrical shock hazards:    a) In the anodizing area, two light switch gang boxes had open holes on the top with visible conductors; and    b) In building six, the Murdock, Inc. hot forming press control cabinets and boxes operating at 3 phase 480 volts, had four large openings with live visible conductors and circuits.
Recent events (2)
  • · I (S) $2200
  • · Z (S) $4900

1910.305 B02 I

Serious Gravity 5 2 instances 12 exposed
Issued
Oct 24, 2013
Abate by
Nov 18, 2013
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  On or about April 26, 2013 and at times prior thereto, in the anodizing area, the paint booth light switches and receptacles had broken or missing cover plates exposing employees to the hazards of electrical shock and fire.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

View Weatherford Aerospace, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339026908.