29 PALMS, CA ·
OSHA Inspection: NATIONAL PARK SERVICE - JOSHUA TREE NP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL PARK SERVICE - JOSHUA TREE NP in 74485 NATIONAL PARK DRIVE PARK HEADQUATERS, 29 PALMS, CA 92277 (NAICS 238390). OSHA activity number 339029399.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL PARK SERVICE - JOSHUA TREE NP
- Site address
- 74485 NATIONAL PARK DRIVE PARK HEADQUATERS
- City
- 29 PALMS
- State
- CA
- ZIP
- 92277
- Mailing
- 74485 NATIONAL PARK DRIVE, 29 PALMS, CA 92277
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238390
- Employees
- 120
- Ownership type
- Federal government (D)
Citations
4 citations on file for this inspection.
1910.178 L04 III
- Issued
- May 29, 2013
- Abate by
- Jun 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: Park headquarters: On or about 24APR13, employees operating powered industrial vehicles were permitted to operate vehicles without their performance being evaluated by the employer for over three years.
Recent events (1)
- · Z (S) $0
1910.242 B
- Issued
- May 29, 2013
- Abate by
- Jun 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: Compound tool room: On or about 24APR13, an air compressor used by the employees for cleaning was not reduced to less than 30 psi.
Recent events (1)
- · Z (S) $0
1910.303 B07 I
- Issued
- May 29, 2013
- Abate by
- Jun 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: Compound tool room: On or about 24APR13, employees were exposed to inadvertent contact with live conductors where an unused opening in a junction box was left uncovered.
Recent events (1)
- · Z (S) $0
1910.303 G02 I
- Issued
- May 29, 2013
- Abate by
- Jun 24, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): Compound storage room: On or about 24APR13, a receptacle outlet was not covered, exposing employees to inadvertent contact with live 120VAC conductors.
Recent events (1)
- · Z (S) $0
More inspections at National Park Service - Joshua Tree NP
View National Park Service - Joshua Tree NP's full OSHA safety record →
More inspections in this industry (NAICS 238390)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339029399.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.