On , OSHA opened a planned safety inspection of ABC DIE CUTTING AND EMBOSSING in 6363 E. 38TH AVE., DENVER, CO 80207 (NAICS 333511). OSHA activity number 339030801.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ABC DIE Cutting and Embossing for free Get an email when a new federal OSHA severe-injury report for ABC DIE Cutting and Embossing is published. One employer, no account, unsubscribe in one click.
Site address
6363 E. 38TH AVE.
City
DENVER
State
CO
ZIP
80207
Mailing
6363 E. 38TH AVE., DENVER, CO 80207
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333511
Employees
24
Ownership type
Private (A)

6 citations on file for this inspection.

1910.24 H

Serious Gravity 1 2 instances 1 exposed
Issued
May 23, 2013
Abate by
Jun 19, 2013
Penalty
Initial $1,020 · Current $816 Reduced
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms.     (a) ABC Die Cutting and Embossing, 6363 E. 38th Ave., Denver, CO 80207; On and before April 30, 2013, the exposing employer failed to ensure that handrails were provided on the exposed sides of two stairways used to access the large format platform between the two large format embossing machines.  Condition exposed employees to trip and fall hazards as they accessed the platform to utilize the large format machines.
Recent events (2)
  • · I (S) $816
  • · Z (S) $1020

1910.147 C01

Serious Gravity 1 1 instance 1 exposed
Issued
May 23, 2013
Abate by
Jul 19, 2013
Penalty
Initial $1,020 · Current $816 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    (A) ABC Die Cutting and Embossing, 6363 E. 38th Ave., Denver, CO 80207; On and before April 30, 2013, the exposing employer failed to develop and implement an energy control program for the various machines with multiple sources of energy which require them.  Condition exposed employees changing machinery components or performing routine maintenance on machinery to laceration and amputation hazards.
Recent events (2)
  • · I (S) $816
  • · Z (S) $1020

1910.147 C04 II B

Serious Gravity 1 1 instance 1 exposed
Issued
May 23, 2013
Abate by
Jul 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(B): Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy had not been developed;    (A0 ABC Die Cutting and Embossing, 6363 E. 38th Ave., Denver, CO 80207; On and before April 30, 20313, the exposing employer did not develop machine specific procedural steps for shutting down, isolating, blocking and securinig machines and equipment for the control of hazardous energy.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 C06 I

Serious Gravity 1 1 instance 1 exposed
Issued
May 23, 2013
Abate by
Jul 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.    (a) ABC Die Cutting and Embossing, 6363 E. 38th Ave., Denver, CO 80207; On and before April 30, 2013, the exposing employer failed to perform annual periodic inspections of the energy control procedures.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
May 23, 2013
Abate by
Jul 19, 2013
Penalty
Initial $1,020 · Current $816 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.     (a) ABC Die Cutting and Embossing, 6363 E. 38th Ave., Denver, CO 80207; On and before April 30, 2013, the exposing employer did not provide machine guarding on the rotating portion of the rear of a Federal Pacific Transformer Company's slitter machine, catalog number T4T15, File No. E37783, Model No. 3613.  Condition exposed employees to the laceration, amputation and pinch point hazards created by the machines rotating bars.
Recent events (2)
  • · I (S) $816
  • · Z (S) $1020

1910.305 G02 III

Serious Gravity 1 2 instances 1 exposed
Issued
May 23, 2013
Abate by
Jul 19, 2013
Penalty
Initial $1,020 · Current $816 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables where not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.    (a)  ABC Die Cutting and Embossing, 6363 E. 38th Ave., Denver, CO 80207;  On and before April 30, 3013, the exposing employer failed to ensure that strain relief was provided on two flexible cords utilized to provide power to the Jogger Aerator Machine, and to the area around the Federal Pacific Transformer Company Slitter machine.  In both instances, power cords were dropped from strutural steel ceiling joists with no strain relief provided.  Condition exposed employees to electric shock hazard as the power cords were used to provide electric power to machines on the floor and insulation was subject to damage.