HIALEAH, FL ·
OSHA Inspection: ACAI INVESTMENTS ,LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ACAI INVESTMENTS ,LLC in 7803 W 25TH CT, HIALEAH, FL 33016 (NAICS 326121). OSHA activity number 339032443.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACAI INVESTMENTS ,LLC
- Site address
- 7803 W 25TH CT
- City
- HIALEAH
- State
- FL
- ZIP
- 33016
- Mailing
- 7803 W 25TH CT, HIALEAH, FL 33016
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326121
- Employees
- 6
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.23 C01
- Issued
- May 16, 2013
- Abate by
- Jun 19, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: On or about April 26, 2013, at the above addressed jobsite, an overhead storage platform, 10 feet above ground, was not provided with guard rails.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.147 C01
- Issued
- May 16, 2013
- Abate by
- Jun 19, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about April 26, 2013, at the above addressed jobsite, the employer had not established a lockout tagout program to ensure the isolation of energy during repair and maintenance of the ZED-300-50 and ZED 300-60 thermoformers.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.212 A01
- Issued
- May 16, 2013
- Abate by
- Jun 12, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: A- On or about April 26, 2013, at the above addressed jobsite, the Zed 300-60 thermoformer did not have guards for the plastic pick up section, and the rollers that picked up the leftover plastic. B- On or about April 26, 2013 The Zed 300-50 thermoformer did not have guards in front of the heating element section.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.215 A04
- Issued
- May 16, 2013
- Abate by
- Jun 19, 2013
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: On or about April 26, 2013, at the aboved adressed location, an Ohio Forge bench grinder did not have a work rest for the employees to grind various pieces of metal.
Recent events (2)
- · I (S) $720
- · Z (S) $1200
1910.305 G01 IV A
- Issued
- May 16, 2013
- Abate by
- Jun 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: A- On or about April 26, 2013, at the above addressed jobsite, at the bench grinder station, extension cords were used as permanent wiring. B- On or about April 26, 2013, at the above adressed jobsite, at the Zed 300-60 station, flexible cords were used as permanent wiring.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.334 A02 II
- Issued
- May 16, 2013
- Abate by
- Jun 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: A- On or about April 26, 2013, at the above addressed jobsite, at the work bench where the bench grinder is located, the employer had extension cords that were frayed. B- On or about April 26, 2013, at the above addressed jobsite, at the ZED 300-60 station, the employer had extensioncords that were frayed.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Acai Investments ,LLC
View Acai Investments ,LLC's full OSHA safety record →
More inspections in this industry (NAICS 326121)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339032443.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.