SKOKIE, IL ·
OSHA Inspection: BOGDAN TRZINSKI
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BOGDAN TRZINSKI in 8747 KEELER AVE., SKOKIE, IL 60076 (NAICS 238160). OSHA activity number 339033698.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOGDAN TRZINSKI
- Site address
- 8747 KEELER AVE.
- City
- SKOKIE
- State
- IL
- ZIP
- 60076
- Mailing
- 4412 RIVER RD., SCHILLER PARK, IL 60176
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 E01
- Issued
- May 7, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $2,400 · Current $1,336 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a) Employees were not provided with safe access to a ladder jack scaffold platform being used at an elevation of approximately 12.9 feet above the ground. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $1336
- · Z (S) $2400
1926.451 G01 I
- Issued
- May 7, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $2,800 · Current $1,560 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) Employees were exposed to the hazard of falling while working from ladder jack scaffold platform elevated approximately 12.9 feet above the ground. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $1560
- · Z (S) $2800
1926.451 G04 I
- Issued
- May 7, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms: a) Employees were working from a pump jack scaffold platform, approximately 17.5 feet above the ground, without the midrail installed between the top edge of the guardrail system and the scaffold platform and endrails installed at the end of the platform. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.452 J02
- Issued
- May 7, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: a) The poles of the pump jack scaffold were not secured at the bottom of the poles. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).