HUNTINGDON, PA —
OSHA Inspection: S.P. MCCARL & COMPANY, INCORPORATED
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of S.P. MCCARL & COMPANY, INCORPORATED in SCI HUNTINGDON 1100 PIKE STREET, HUNTINGDON, PA 16652 (NAICS 238220). OSHA activity number 339035842.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- S.P. MCCARL & COMPANY, INCORPORATED
- Site address
- SCI HUNTINGDON 1100 PIKE STREET
- City
- HUNTINGDON
- State
- PA
- ZIP
- 16652
- Mailing
- 2221 NINTH AVENUE, ALTOONA, PA 16603
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.651 L
- Issued
- May 29, 2013
- Abate by
- Jun 24, 2013
- Penalty
- Initial $4,200 · Current $3,360 Reduced
General-duty citation text
29 CFR 1926.651(l): Guardrails complying with 1926.502(b) were not provided where walkways were 6 feet (1.8m) or more above lower levels. a) Trench - Employees were exposed to a 7 foot - 7 inch fall hazard as they used a steel plate walkway to cross a trench and were not protected by a guardrail system, on or about May 1, 2013. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3360
- — Z (S) $4200
1926.652 A01
- Issued
- May 29, 2013
- Abate by
- Jun 24, 2013
- Penalty
- Initial $4,900 · Current $3,920 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). a) Trench - Employees working in a trench 8 - 11 feet deep were exposed to potential cave-in hazards while working in an inadequate job-made protective system, on or about May 1, 2013. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $3920
- — Z (S) $4900
1926.651 K01
- Issued
- May 29, 2013
- Abate by
- Jul 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift. a) Trench - Employees worked in a trench 8 - 11 feet deep and an inspection was not conducted by a competent person as evidenced by hazards such as, but not limited to, inadequate cave-in protection, improper use of a ladder, ladder not extending at least 3 feet above the landing surface, walkway without fall protection such as guardrails, on or about May 1, 2013. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.21 B02
- Issued
- May 29, 2013
- Abate by
- Jul 3, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury. a) Trench - Employees were not provided adequate training in the recognition and avoidance of hazards as evidenced and noted by hazards such as but not limited to: inadequate cave-in protection, improper use of a ladder, ladder not extending at least 3 feet above the landing surface, walkway without fall protection such as guardrails, on or about May 1, 2013. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.652 C04
- Issued
- May 29, 2013
- Abate by
- Jun 24, 2013
- Penalty
- Initial $4,900 · Current $3,920 Reduced
General-duty citation text
29 CFR 1926.652(c)(4): Support systems, shield systems, and other protective systems that did not utilize Option 1, Option 2, or Option 3 were not approved by a registered professional engineer. a) Trench - Employees working in a trench 8 - 11 feet deep were exposed to potential cave-in hazards while working within an job-made protective system not designed by a registered professional engineer, on or about May 1, 2013. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $3920
- — Z (S) $4900
1926.1053 B01
- Issued
- May 29, 2013
- Abate by
- May 29, 2013
- Penalty
- Initial $2,100 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend to at least 3 feet (.9m) above the upper landing surface to which the ladder was used to gain access nor was the ladder secured at it's top to a ridgid support and a grasping device, such as a grabrail, provided to assist the employee in mounting and dismounting the the ladder: a) Trench - Employees used a 10 ft. Werner portable step ladder to access and exit a trench and the top of the ladder extended between 18 - 24 inches above the pavement level exposing them to a fall hazard, on or about May 1, 2013. No abatement certification or documentation required.
Recent events (2)
- — I (O) $1680
- — Z (S) $2100
1926.1053 B04
- Issued
- May 29, 2013
- Abate by
- May 29, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were not used for the purpose for which they were designed. a) Trench - Employees used a 10 ft. Werner portable step ladder to access and egress a trench and the ladder was in the folded and closed position exposing them to a fall hazard, on or about May 1, 2013. No abatement certification or documentation required.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at S.P. Mccarl & Company, Incorporated
View S.P. Mccarl & Company, Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339035842.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.