Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NATHAN STEEL CORPORATION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of NATHAN STEEL CORPORATION in 36 WURZ AVENUE, UTICA, NY 13502 (NAICS 332999). OSHA activity number 339036188.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nathan Steel Corporation — free Get an email when a new federal OSHA severe-injury report for Nathan Steel Corporation is published. One employer, no account, unsubscribe in one click.
Site address
36 WURZ AVENUE
City
UTICA
State
NY
ZIP
13502
Mailing
36 WURZ AVENUE, UTICA, NY 13502
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
13
Ownership type
A

12 citations on file for this inspection.

1910.107 D02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 24, 2013
Abate by
Sep 30, 2013
Penalty
Initial $1,360 · Current $816 Reduced
29 CFR 1910.107(d)(2): All spraying areas were not provided with mechanical ventilation adequate to remove flammable vapors, mists, or powders to a safe location and to confine and control combustible residues so that life is not endangered.      a) Spray painting area, on or about 5/2/13: Mechanical ventilation was not provided for spray areas in which flammable primers and solvents were applied.      Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $816
  • — Z (S) $1360

1910.107 E05

Serious Gravity 5 3 instances 2 exposed
Issued
Jul 24, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(e)(5): Containers supplying spray nozzles were not closed or provided with metal coverings kept closed.:   a) Spray painting area, on or about 5/2/13: Cans of flammable blue, green and yellow colored primers supplying spray nozzles were not kept covered.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 G02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 24, 2013
Abate by
Aug 28, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:   a) Spray painting area, on or about 5/9/13: Spray areas were not cleaned of residue from flammable primers used in spray painting operations.   Abatement certification must be submitted for this item
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 G03

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 24, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(3): Residue scrapings and debris contaminated with residue were not immediately removed from the premises and properly disposed. Approved metal waste cans were not provided wherever rags or waste were impregnated with finishing material; and all such rags or waste were not deposited therein immediately after use. The contents of waste cans were not properly disposed of at least once daily or at the end of each shift.   a) Spray painting area, on or about 5/9/13: Rags containing flammable primer residue and solvent residue containing xylene were not placed in the closed metal cans that were provided.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 C05

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 24, 2013
Penalty
Initial $1,360 · Current $816 Reduced
29 CFR 1910.107(c)(5):  Electrical equipment not approved for locations containing both deposits of readily ignitable residues and explosive vapors was present in spraying area(s):    a) Spray painting area, on or about 5/2/13: Electrical outlets, not suitable for Class 1, Division 2 locations, were installed and used in an area where flammable primers and solvents were sprayed.
Recent events (2)
  • — I (S) $816
  • — Z (S) $1360

1910.147 D03

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jul 24, 2013
Abate by
Aug 28, 2013
Penalty
Initial $1,700 · Current $0 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:   a) Press brake area, on or about 5/2/13: The foot pedal for the HTC press brake was not locked out or otherwise isolated and under full control of the employee changing the blade.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1700

1910.157 G02

Serious Gravity 1 4 instances 6 exposed
Issued
Jul 24, 2013
Penalty
Initial $1,020 · Current $612 Reduced
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:      a) Welding areas, on or about 5/9/13: Annual training fire extinguishers was not provided for welders. Last training was provided in the 2011 calendar year.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

1910.252 A02 III A

Serious Gravity 1 1 instance 5 exposed
Issued
Jul 24, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.252(a)(2)(iii)(A): The employer did not provide fire watchers whenever welding or cutting was performed in locations where other than a minor fire might develop:   a) Welding areas, on or about 5/9/13: A system for fire watching was not set up to protect against igniting residue from spray painting area within 30 feet of welding applications.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.252 A02 III B

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 24, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.252(a)(2)(iii)(B): The employer did not ensure that fire watchers had fire extinguisher equipment readily available and were trained in its use:   a) Welding area, on or about 5/9/13: Welders working in an area across the aisle and within 35 feet from spray painting operations were not trained in fire extinguisher use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.254 D01

Serious Gravity 1 1 instance 5 exposed
Issued
Jul 24, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.254(d)(1): Workmen assigned to operate or maintain arc welding equipment were not acquainted with the requirements of 29 CFR 1910.254(d) and 29 CFR 1910.252(a), (b), and (c):    a) Welding areas, on or about 5/9/13: Employees performing Gas Metal Arc Welding (MIG) were not trained on the provisions of 1910.252 pertaining to (a) fire prevention and protection, and (c) health protection and ventilation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 3 exposed
Issued
Jul 24, 2013
Penalty
Initial $1,020 · Current $612 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:      a) Throughout the facility, on or about 5/2/13: Three employees were not provided with information and training on the hazards to which they are exposed including, but not limited to heavy metal fumes, flammable primers and flammable solvents such as xylene.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

1910.1020 G01

Other-than-serious 1 instance 13 exposed
Issued
Jul 24, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1020(g)(1): Upon an employee's first entering into employment, and at least annually thereafter, the employer did not inform current employees covered by this section:  a) Throughout the facility, on or about 5/9/13: Employees were not notified of their right to access medical and exposure records including, but not limited to, employee monitoring results for monitoring performed on 5/1/12. In addition, employees were not notified of the availability of records, person keeping records and how to obtain copies of records.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Nathan Steel Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339036188.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.