Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELIXIR INDUSTRIES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ELIXIR INDUSTRIES, INC. in 1300 POPE DRIVE, DOUGLAS, GA 31533 (NAICS 332999). OSHA activity number 339037673.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Elixir Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Elixir Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1300 POPE DRIVE
City
DOUGLAS
State
GA
ZIP
31533
Mailing
1300 POPE DRIVE, DOUGLAS, GA 31533
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
153
Ownership type
A

7 citations on file for this inspection.

1910.23 D01

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 28, 2013
Abate by
Nov 22, 2013
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers shall be equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section.  a). Waste Water Treatment Area- On or about and times prior to 2 May 2013, there was a blue colored stairway not equipped with intermediate rails, thus exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $1530
  • — Z (S) $2550

1910.147 C04 I

Serious Gravity 5 2 instances 3 exposed
Issued
Oct 28, 2013
Abate by
Nov 22, 2013
Penalty
Initial $4,250 · Current $2,550 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   a). Club Car Area- On or about and times prior to 26 April 2013, energy control procedures were not utilized when replacing dies on the Punch Press (Puncher #1), thus exposing employees to amputation injuries.  b). Club Car Area- On or about and times prior to 26 April 2013, energy control procedures were not utilized when replacing dies on the bender machines, thus exposing employees to amputation injuries.
Recent events (2)
  • — I (S) $2550
  • — Z (S) $4250

1910.151 C

Serious Gravity 10 2 instances 1 exposed
Issued
Oct 28, 2013
Abate by
Nov 22, 2013
Penalty
Initial $7,000 · Current $4,200 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.  a). Waste Water Treatment Area- On or about 1 May 2013, the emergency eyewash/shower station was not located immediately adjacent to the work platform where the employees are exposed to sulfuric acid. The employees would have to travel approximately 25 feet that includes descending two stairways. Furthermore, the station was not in suitable condition in which the dust caps were damaged and not placed on the spray heads, thus exposing employees to hazards associated with sulfuric acid.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $7000

1910.157 C01

Serious Gravity 5 2 instances 2 exposed
Issued
Oct 28, 2013
Penalty
Initial $2,890 · Current $1,734 Reduced
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.   a). Pallet Building and Packing Area- On or about 1 May 2013, there was a portable fire extinguisher not mounted, thus exposing employees to fire hazards.    b). Pallet Building and Packing Area- On or about 1 May 2013, there was a portable fire extinguisher not easily accessible in which material handling equipment such as pallets were placed in front of it, thus exposing employees to fire hazards.
Recent events (2)
  • — I (S) $1734
  • — Z (S) $2890

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 28, 2013
Abate by
Nov 22, 2013
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.  a). Fabrication Department Area- On or about and times prior to 2 May 2013, there was one unused opening on a 120-Volt Delta Service grinder, thus exposing employees to electrical and life safety hazards.
Recent events (2)
  • — I (S) $1530
  • — Z (S) $2550

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 28, 2013
Penalty
Initial $2,168 · Current $1,301 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.  a). Waste Water Treatment Area- On or about and times prior to 1 May 2013, there was no strain relief on both ends of the electrical cord used to energize a Lightnin mixer, Type C5, ID# 20736425JQK in which the internal wiring was revealed, thus exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1300.8
  • — Z (S) $2168

1910.1200 F06

Other-than-serious 2 instances 1 exposed
Issued
Oct 28, 2013
Abate by
Nov 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6): Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked in accordance with either f(6)(i) or f(6)(ii) of this section.   a). Fabrication Department Area- On or about 2 May 2013, there was a plastic container that contained hydraulic oil  that was not labeled, tagged, or marked with its contents and other hazard information, thus exposing employees to chemical hazards.    b). Fabrication Department Area- On or about 2 May 2013, there was a plastic spray bottle that contained detergent that was not labeled, tagged, or marked with its contents and other hazard information, thus exposing employees to chemical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Elixir Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339037673.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.