Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: TOM BURGE FENCE & IRON INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of TOM BURGE FENCE & IRON INC in 6770 W 152ND TERRACE, OVERLAND PARK, KS 66223 (NAICS 238990). OSHA activity number 339039331.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch TOM Burge Fence & Iron INC for free Get an email when a new federal OSHA severe-injury report for TOM Burge Fence & Iron INC is published. One employer, no account, unsubscribe in one click.
Site address
6770 W 152ND TERRACE
City
OVERLAND PARK
State
KS
ZIP
66223
Mailing
6770 W 152ND TERRACE, OVERLAND PARK, KS 66223
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
35
Ownership type
A

1 citation on file for this inspection.

1910.94 C04 IV

Serious Gravity 5 7 instances 1 exposed
Issued
Sep 20, 2013
Abate by
Nov 7, 2013
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.94(c)(4)(iv): Spray rooms used for production spray-finishing operations shall conform to the requirements for spray booths.     Employees were exposed to injury from fire and explosion hazards.  The spray painting room was not designed, constructed or used in accordance with 29 CFR 1910.107 as follows:     a)  Spray rooms shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantially noncombustible material may be sued for intermittent or low volume spraying.     b)  The interior surfaces of spray rooms shall be smooth and continuous without edges and otherwise designed to prevent pocketing of residues and facilitate cleaning and washing.     c)  All spray rooms shall be provided with mechanical ventilation adequate to remove flammable vapors, mists, or powders to a safe location and to confine and control combustible residues so that life is not endangered.     d)  The quantity of flammable or combustible liquids kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift.     e)  Spray rooms shall be provided with automatic sprinklers.     f)  An adequate supply of suitable portable fire extinguishers shall be installed near all spraying rooms.   g) All spraying rooms shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary.    29 CFR 1903.19(d)(1) requires certification and documentation that the abatement of the above violation is complete.
Recent events (2)
  • · I (S) $1750
  • · Z (S) $3500

View TOM Burge Fence & Iron INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339039331.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.