Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: J. EME CONSTRUCTION, LLC

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of J. EME CONSTRUCTION, LLC in 236 N. MAIN STREET, WEST MILTON, OH 45383 (NAICS 238160). OSHA activity number 339042095.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J. EME Construction, LLC for free Get an email when a new federal OSHA severe-injury report for J. EME Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
236 N. MAIN STREET
City
WEST MILTON
State
OH
ZIP
45383
Mailing
108 HAWKER ST., DAYTON, OH 45410
Inspection type
Programmed Related (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
Private (A)

5 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 5 exposed
Issued
May 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $2,520 · Current $2,520
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person.    Workers were engaged in residential construction activities re-roofing an existing single-family house. Workers were exposed to potential electrocution and fall hazards in that  regular and frequent inspections by a competent person was not conducted to ensure that the job site, materials, and equipment such as electrical service and fall protection systems were maintained and utilized in a safe manner.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (1)
  • · Z (S) $2520

1926.503 A01

Serious Gravity 5 1 instance 5 exposed
Issued
May 24, 2013
Abate by
Jul 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:     Workers were observed engaged in residential construction activities re-roofing an existing single-family house. Workers were exposed to potential 23.7 foot fall hazards in that workers were not properly trained in fall protection criteria.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (1)
  • · Z (S) $0

1926.404 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
May 24, 2013
Abate by
May 24, 2013
Penalty
Initial $1,800 · Current $1,800
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection.    Workers were engaged in residential construction activities re-roofing an existing single-family house. Located along the side area of the house worker(s) utilized a DeWalt circular saw that was connected to the electrical service with a orange  50.0 foot extension cord. Worker(s) were exposed to potential electrocution hazards in that the electrical service was not protected with a ground-fault circuit interrupter and an assured equipment grounding conductor program was not in place.
Recent events (1)
  • · Z (S) $1800

1926.404 F06

Serious Gravity 5 1 instance 1 exposed
Issued
May 24, 2013
Abate by
May 24, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:   Workers were engaged in residential construction activities re-roofing an existing single-family house. Located along the side area of the house worker(s) utilized a DeWalt circular saw that was connected to the electrical service with a 50 foot extension cord. Worker(s) were exposed to potential electrocution hazards in that the extension cord was missing a grounding pin.
Recent events (1)
  • · Z (S) $0

1926.501 B13

Serious Gravity 10 4 instances 4 exposed
Issued
May 24, 2013
Abate by
May 24, 2013
Penalty
Initial $2,520 · Current $2,520
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     Workers were observed engaged in residential construction activities re-roofing an existing single-family house. Located the upper roof area workers were exposed to potential 23.7 foot fall hazards in that a proper fall protection system was not utilized.