Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STAR ELECTRIC COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STAR ELECTRIC COMPANY, INC. in ONE WATERFRONT PLACE, PITTSBURGH, PA 15222 (NAICS 238210). OSHA activity number 339045429.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Star Electric Company, INC. — free Get an email when a new federal OSHA severe-injury report for Star Electric Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
ONE WATERFRONT PLACE
City
PITTSBURGH
State
PA
ZIP
15222
Mailing
120 23RD STREET, PITTSBURGH, PA 15215
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
77
Ownership type
A

2 citations on file for this inspection.

1926.453 B02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 9, 2013
Penalty
Initial $3,500 · Current $3,500
29 CFR 1926.453(b)(2)(v): A body belt was not worn and a lanyard attached to the boom or basket when working from an aerial lift:     a) Jobsite, One Waterfront Place: On or about April 30, 2013, during construction activities, the employer did not ensure that an employee in the bucket of an aerial lift was using fall protection systems/devices, where exposed to a fall hazard of approximately 20 feet.   Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e).
Recent events (1)
  • — Z (S) $3500

1926.416 A01

Other-than-serious 1 instance 1 exposed
Issued
Jul 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.416(a)(1): The employer permitted an employee to work in such proximity to any part of an electric power circuit that the employee could have contacted the electric power circuit in the course of work, and the employee was not protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means:      a) Jobsite, One Waterfront Place: On or about April 30, 2013, during construction activities, the employer did not ensure that an employee moving a temporary power line was protected against accidental shock in that the power going to the line was not controlled prior to the start of work.
Recent events (1)
  • — Z (O) $0

View Star Electric Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339045429.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.