Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J.L ROOFING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of J.L ROOFING in 16570 N. BROOKDALE PKWY, NAMPA, ID 83687 (NAICS 238160). OSHA activity number 339046856.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J.L Roofing — free Get an email when a new federal OSHA severe-injury report for J.L Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
J.L ROOFING
Site address
16570 N. BROOKDALE PKWY
City
NAMPA
State
ID
ZIP
83687
Mailing
1695 WINDEMERE DRIVE, MOUNTAIN HOME, ID 83647
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
May 16, 2013
Abate by
May 22, 2013
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) On or about May 6, 2013, and at times prior thereto, two employees involved in roofing activities on a 6 in 12 pitch roof structure without a fall protection system and exposed to a fall hazard ranging from heights 10.6 feet up to 18 feet from the ground to eaves.       NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2000

1926.1051 A

Serious Gravity 5 1 instance 2 exposed
Issued
May 16, 2013
Abate by
May 22, 2013
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided:    (a)  Front of the structure over the main garage:  On or about May 6, 2013, and at times prior thereto, the employer did not provide a safe means of access/egress where there was a 3 1/2 foot break in elevation between roof levels.    Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 1 1 instance 2 exposed
Issued
May 16, 2013
Abate by
May 16, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access.    (a)  In front of the structure above the main garage: On or about May 6, 2013, the extension ladder was only extended approximately 1 1/2 feet above the landing.    Note: Abatement certification IS NOT required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View J.L Roofing's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339046856.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.