OSHA Inspection: DAVE'S FLOW MEASUREMENT, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DAVE'S FLOW MEASUREMENT, LLC in 1012 NE FRONTAGE ROAD, FORT COLLINS, CO 80524 (NAICS 332999). OSHA activity number 339047995.

Watch Dave'S Flow Measurement, LLC — free Get an email when a new federal OSHA severe-injury report for Dave'S Flow Measurement, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1012 NE FRONTAGE ROAD
City
FORT COLLINS
State
CO
ZIP
80524
Mailing
1012 NE FRONTAGE ROAD, FORT COLLINS, CO 80524
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
26
Ownership type
A

10 citations on file for this inspection.

1910.107 B05 IV

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1250.00 Reduced
29 CFR 1910.107(b)(5)(iv):  Space within the spray booth(s) on the downstream and upstream sides of filters was not protected with approved automatic sprinklers:       (a) Daves Flow Measurement, LLC @ 1012 NE Frontage Rd., Fort Collins, CO 80524:  On and before April 18th, 2013, the employer did not ensure that the Standard Mid-Size Finishing spray booth Model # MSFB-1000 was protected on the downstream and upstream side of the filters by automatic sprinklers.  The spray booth was not equipped with an automatic sprinkler system. This condition exposed the employees to a fire hazard.
Recent events (2)
  • — I (O) $1250
  • — Z (S) $1785

1910.107 E02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1250.00 Reduced
29 CFR 1910.107(e)(2): The employer did not ensure that the quantity of flammable or combustible liquids kept in the vicinity of spraying operations was the minimum required for operations and should ordinarily not exceed a supply of one day or one shift:       (a) Dave's Flow Measurement, LLC @ 1012 NE Frontage Rd, Fort Collins, CO 80524:  On and before April 18th, 2013, the employer did not ensure that the quantity of flammable or combustible liquids kept in the vicinity of spraying operations was the minimum required for operations and should ordinarily not exceed a supply of 1 day or one shift. Employees painted metal meter tubes. The quantity of flammable paints and solvents stored within the spray booth and adjacent to the spraying operation exceeded one day supply.
Recent events (2)
  • — I (O) $1250
  • — Z (S) $1785

1910.107 E03

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1250.00 Reduced
29 CFR 1910.107(e)(3): Open or glass container(s) were used for bringing flammable or combustible liquids into spray finishing room(s):       (a) Daves Flow Measurement, LLC @ 1012 NE Frontage Rd., Fort Collins, CO 80524:  On and before April 18th, 2013, the employer did not ensure that open containers used for bringing flammable or combustible liquids into the spray finishing booth were closed. The employer had an open container of xylene within the spray booth This condition exposed the employees to a fire hazard.
Recent events (2)
  • — I (O) $1250
  • — Z (S) $1785

1910.178 L01 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1785.00 · Current $1248.00 Reduced
29 CFR 1910.178(l)(1)(i): Operators were not trained in the safe operation of powered industrial trucks:       (a) Dave's Flow Measurement, LLC, Fort Collins, CO 80528: The employer did not ensure all forklift operators were trained in operation of powered industrial trucks in that the operators were not trained in the use of forklifts prior to their use.  This condition exposed the employees to the hazard of improper forklift operation.       Abatement Note:  Training shall consist of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.
Recent events (2)
  • — I (O) $1248
  • — Z (S) $1785

1910.134 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c)(1):  A written respiratory protection program with worksite specific procedures, as specified in subparagraphs (c)(1)(i) through (ix) of this section, was not established and implemented where respirator(s) were necessary to protect the health of the employee or whenever respirator(s) were required by the employer:     (a)Dave's Flow Measurement, LLC @ 1012 NE Frontage Rd., Fort Collins, CO 80524:  On and before April 18th, 2013, the employer did not have a written respiratory protection program with work-site specific procedures, as specified in subparagraphs (c)(1)(i) through (ix) of this section.  The program was not established and implemented whenever respirators were required by the employer, in that the employer required the use of a half-face, negative pressure, air-purifying respirator during spray operations.  This hazard exposed the employee to the lack of knowledge of proper respirator use.       Abatement Note:  The employer shall include in the program the following provisions of this section, as applicable:     (1)        Procedures for selecting respirators for use in the workplace;     (2)        Medical evaluations of employees required to use respirators;     (3)        Fit testing procedures for tight-fitting respirators;     (4)        Procedures for proper use of respirators in routine and reasonably foreseeable emergency situations;     (5)        Procedures and schedules for cleaning, disinfecting, storing, inspecting, repairing, discarding, and otherwise maintaining respirators;     (6)        Procedures to ensure adequate air quality, quantity, and flow of breathing air for atmosphere-supplying respirators;     (7)        Training of employees in the respiratory hazards to which they are potentially exposed during routine and emergency situations;     (8)        Training of employees in the proper use of respirators, including putting on and removing them, any limitations on their use, and their maintenance; and     (9)        Procedures for regularly evaluating the effectiveness of the program.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 D01 III

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard in the workplace:     (a) Dave's Flow Measurement, LLC @ 1012 NE Frontage Rd., Fort Collins, CO 80524: On and before April 18th, 2013, the employer did not identify and evaluate the respiratory hazard in the workplace, in that, employees painted meter tubes. The preparation, painting, and clean-up operations generated aerosols and vapors containing xylene. The employer did not evaluate employee exposure to vapors and aerosols. This condition potentially exposed employees to a respiratory hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 E01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:     (a) Dave's Flow Measurement, LLC @ 1012 NE Frontage Rd., Fort Collins, CO 80524: On and before April 18th, 2013, the employer had not provided medical evaluations to determine the employee's ability to use a respirator, before the employees used the respirator. Employees painted metal meter tubes. The preparation, painting, and clean-up operations generated aerosols and vapors containing toluene, n-butyl acetate, tert-buytl acetate, ethyl benzene, and xylene which was present in the paint product. The employees conducted spray operations while wearing half-face, negative pressure, air-purifying respirator. This hazard exposed the employee to health hazards of using a respirator unsafely.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 F02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(2):  The employer did not ensure that employees using tight-fitting facepiece respirators were fit tested prior to initial use of the respirator, whenever a different respirator facepiece was used, and at least annually thereafter:     (a)Dave's Flow Measurement, LLC @ 1012 NE Frontage Rd, Fort Collins, CO 80524: On and before April 18th, 2013 the employer did not ensure that when an employee using half-face, negative pressure, air-purifying respirator were fit tested prior to initial use of the respirators, whenever a different respirator facepiece was used, and at least annually thereafter.  This hazard exposed the employee to the lack of knowledge of proper respirator use.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 K03

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(3):  The employer did not provide training prior to requiring employees to use respirators in the workplace:     (a) Dave's Flow Measurement, LLC @ 1012 NE Frontage Rd., Denver, CO 80524:  On and before April 18th, 2013, the employer did not provide respirator training prior to requiring the use of respirators in that the employees used a half-face, negative pressure, air-purifying respirator while conducting spraying operations.  This hazard exposed the employee to the lack of knowledge of proper respirator use.       Abatement Note:  The employer shall ensure that each employee can demonstrate knowledge of at least the following:     (1)        Why the respirator is necessary and how improper fit, usage, or maintenance can compromise the protective effect of the respirator;     (2)        What the limitations and capabilities of the respirator are;     (3)        How to use the respirator effectively in emergency situations, including situations in which the respirator malfunctions;     (4)        How to inspect, put on and remove, use, and check the seals of the respirator;     (5)        What the procedures are for maintenance and storage of the respirator;     (6)        How to recognize medical signs and symptoms that may limit or prevent the effective use of respirators; and     (7)        The general requirements of this section.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trained about is introduced into their work area:     (a)Dave's Flow Measurement, LLC @ 1012 NE Frontage Rd., Fort Collins, CO 80524:  On and before April 18th, 2013, the employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trained about is introduced into their work area.     Abatement Note:     (a)        Employees shall be informed of:     (1)        Any operation in their work area where hazardous chemicals are present; and,     (2)        The location and availability of the written hazard communication program, including the required list(s) of hazardous chemicals, and material safety data sheets required by this section.     (b)        Employee training shall include at least:     (1)        Methods and observations that may be used to detect the presence or release of a hazardous chemical in the work area (such as monitoring conducted by the employer, continuous monitoring devices, visual appearance or odor of hazardous chemicals when being released, etc.);     (2)        The physical and health hazards of the chemicals in the work area;     (3)        The measures employees can take to protect themselves from these hazards, including specific procedures the employer has implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures, and personal protective equipment to be used;     (4)        The details of the hazardous communication program developed by the employer, including an explanation of the labeling system and the material safety data sheet, and how employees can obtain and use the appropriate hazard information.