Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HI-TECH ELECTRIC, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HI-TECH ELECTRIC, INC. in 100 KANAWHA BLVD EAST, CHARLESTON, WV 25301 (NAICS 238210). OSHA activity number 339048191.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hi-Tech Electric, INC. — free Get an email when a new federal OSHA severe-injury report for Hi-Tech Electric, INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 KANAWHA BLVD EAST
City
CHARLESTON
State
WV
ZIP
25301
Mailing
12138 KEVIN AVENUE, ASHLAND, KY 41102
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
3
Ownership type
A

7 citations on file for this inspection.

1926.95 A

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 26, 2013
Abate by
Aug 7, 2013
Penalty
Initial $1,800 · Current $900 Reduced
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact.     (a)  100 Kanawha Boulevard East, Charleston, WV:  Employees were not wearing protective gloves recommended by the Material Safety Data Sheet when using the Cantex Conduit Solvent Cement that is a skin irritant and can cause dermatitis as determined on May 7, 2013.     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1800

1926.102 A

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 26, 2013
Abate by
Aug 7, 2013
Penalty
Initial $1,080 · Current $540 Reduced
29 CFR 1926.102(a):   Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:    (a)  100 Kanawha Boulevard East, Charleston, WV:  Employees were not provided safety glasses on site while working close to trench digging operations as determined on May 7, 2013.    ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $540
  • — Z (S) $1080

1926.651 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 26, 2013
Abate by
Aug 7, 2013
Penalty
Initial $2,520 · Current $1,260 Reduced
29 CFR 1926.651(c)(2):     A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:    (a)  100 Kanawha Boulevard East, Charleston, WV:  The employer did not provide a safe means of egress at least every twenty-five feet for employees working in a trench that was 77 inches deep.  Employees entered the trench from one end and walked thirty feet down the trench to their last pipe connection as determined on May 7, 2013.    ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2520

1926.21 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 26, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.21(b)(2):   The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  (a)  100 Kanawha Boulevard East, Charleston, WV:  The employer did not provide training on unsafe working conditions as evidenced by the safety hazards found on site including, but not limited to, employees employees working in a vertical walled trench, with a maximum depth of 77 inches, with no protective system in place to prevent a cave-in, as determined on May 7, 2013.  ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.651 J02

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 26, 2013
Abate by
Aug 7, 2013
Penalty
Initial $1,080 · Current $540 Reduced
29 CFR 1926.651(j)(2):     Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.    (a)  100 Kanawha Boulevard East, Charleston, WV:  Excavated dirt and rocks that were not secured by a retaining device were not kept at least two feet back from the edge of a trench that employees were working in to prevent the materials from falling or rolling into the trench as determined on May 7, 2013.    ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $540
  • — Z (S) $1080

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 26, 2013
Abate by
Aug 7, 2013
Penalty
Initial $2,520 · Current $1,260 Reduced
29 CFR 1926.652(a)(1):     Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c).     (a)  100 Kanawha Boulevard East, Charleston, WV:  Employees were working in a vertical walled trench that had a maximum depth of 77 inches.  There were no protective systems in place to prevent a cave-in such as a trench box, sloping, or benching of the trench as determined on May 7, 2013.      ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2520

1926.651 K01

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 26, 2013
Abate by
Aug 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.651(k)(1):   Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems:  (a) 100 Kanawha Boulevard East, Charleston, WV:  A competent person that was knowledgeable in excavation safety was not on site conducting inspections to identify the hazards found with a 77 inch deep trench that employees were working in including the lack of cave-in protection, improper placement of the spoil pile, and the lack of proper means of egress from the trench as determined on May 7, 2013.  ABATEMENT DOCUMENTATION REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Hi-Tech Electric, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339048191.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.