UTICA, NY —
OSHA Inspection: DAMIR BAJREKTAREVIC DBA GOLDEN HANDS GENERAL CONTRACTOR
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DAMIR BAJREKTAREVIC DBA GOLDEN HANDS GENERAL CONTRACTOR in PARKWAY PIZZA, 1250 CULVER AVENUE, UTICA, NY 13501 (NAICS 238140). OSHA activity number 339053993.
Where did this inspection happen?
- Site address
- PARKWAY PIZZA, 1250 CULVER AVENUE
- City
- UTICA
- State
- NY
- ZIP
- 13501
- Mailing
- 1572 DELAWARE AVENUE, UTICA, NY 13502
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.404 B01 II
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) South side of building, on or about 5-7-13: One employee was operating a table saw that was powered by a generator that was not protected by a ground fault circuit interrupter (GFCI).
Recent events (1)
- — Z (S) $1200
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $2000.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) Entire worksite, on or about 2-19-13: One employee was working on various scaffolds without the training necessary to recognize the hazards associated with scaffold work.
Recent events (1)
- — Z (S) $2000
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(b)(1): 29 CFR 1926.450(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports: a) East side of building, on or about 5-7-13: One employee was working on a scaffold that was not fully planked, exposing the employee to a fall hazard of 7 feet 4 inches.
Recent events (1)
- — Z (S) $0
1926.451 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) East side of building, on or about 5-7-13: One employee was working on three separate scaffold platforms that were less than 18 inches wide, exposing the employee to a fall hazard of 7 feet 4 inches and/or 5 feet.
Recent events (1)
- — Z (S) $0
1926.451 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) East side of building, on or about 5-7-13: One employee was working on scaffold systems that did not have base plates and mudsills under the scaffold legs.
Recent events (1)
- — Z (S) $0
1926.451 C02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: a) East side of building, on or about 5-7-13: One employee was working on scaffold systems that were not erected upon ground that was sound, level, and rigid.
Recent events (1)
- — Z (S) $0
1926.452 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frame scaffold(s) were not properly erected to secure vertical members laterally and to align them so that the erected scaffold was plumb, square, and rigid: a) East side of building, on or about 5-7-13: One employee was working on multiple scaffold systems that were not erected so that they were plumb, level, and square.
Recent events (1)
- — Z (S) $0
1926.1053 B04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were not used for the purpose for which they were designed: a) East side of building, on or about 5-7-13: One employee was working on a scaffold system that was erected using a step ladder that was not being used as designed or for its intended purpose.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339053993.