Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RUSSELL STOVER CANDIES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RUSSELL STOVER CANDIES, INC. in 1997 PECAN DELIGHT AVE., CORSICANA, TX 75110 (NAICS 445292). OSHA activity number 339054298.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Russell Stover Candies, INC. — free Get an email when a new federal OSHA severe-injury report for Russell Stover Candies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1997 PECAN DELIGHT AVE.
City
CORSICANA
State
TX
ZIP
75110
Mailing
1997 PECAN DELIGHT AVE., CORSICANA, TX 75110
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
445292
Employees
2500
Ownership type
A

9 citations on file for this inspection.

1910.119 D03 I D

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 20, 2013
Abate by
Mar 17, 2014
Penalty
Initial $7,000 · Current $5,600 Reduced
29 CFR 1910.119(d)(3)(i)(D): Information pertaining to the equipment in the process did not include relief system design and design basis.       On or about May 8, 2013, and at times prior thereto, the employer failed to ensure the process safety information for the 38 Degree engine room included the design and design basis for the ammonia relief system header and outlet piping from the relief valve(s) to the header. This condition exposed employees to inhalation, fire, and explosion hazards.
Recent events (2)
  • — I (S) $5600
  • — Z (S) $7000

1910.119 D03 I H

Other-than-serious 1 instance 2 exposed
Issued
Aug 20, 2013
Abate by
Mar 17, 2014
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.119(d)(3)(i)(H): Process safety information pertaining to the equipment in the process did not include the safety systems (e.g., interlocks, detection or suppression systems).      On or about May 8, 2013, and times prior thereto, in the 38 degree engine room, the employer did not ensure that process safety information pertaining to the emergency cutouts for equipment was documented as part of the process safety information. This condition exposed employees to inhalation, fire, and explosion hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $7000

1910.119 E05

Serious Gravity 10 10 instances 4 exposed
Issued
Aug 20, 2013
Abate by
Sep 18, 2013
Penalty
Initial $7,000 · Current $5,600 Reduced
29 CFR 1910.119(e)(5): The employer did not establish a system to assure that the recommendations were resolved in a timely manner and that the resolution was documented.      On or about May 8, 2013, and times prior thereto, the employer did not ensure that recommendation numbers 12, 18, 22, 24, 38, 41, 43, 56, 63 and 71 contained in the 2010 Process Hazard Analysis were resolved in a timely manner and the resolution(s) were properly documented. These conditions exposed employees to hazards of fire, explosion, and/or inhalation of ammonia vapors.
Recent events (2)
  • — I (S) $5600
  • — Z (S) $7000

1910.119 J04 II

Serious Gravity 10 6 instances 4 exposed
Issued
Aug 20, 2013
Abate by
Mar 17, 2014
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.119(j)(4)(ii): The inspection and testing procedures did not follow recognized and generally accepted good engineering practices.   The employer did not ensure inspections and tests performed on process equipment to maintain its on-going mechanical integrity followed recognized and generally accepted good engineering practices (RAGAGEP).  The violation occurred in the 38 degree engine room on or about May 8, 2013, and at times prior thereto, where the employer failed to ensure inspection and tests of ammonia refrigeration equipment cutouts followed RAGAGEP such as IIAR Bulletin 110. Identified cutouts include but are not limited to:           a.    Ammonia Compressor (RC1)        b.    Ammonia Compressor (RC3)        c.    Accumulator (4)        d.    Accumulator (5)        e.    Surge Drum        f.     Water Heat Exchanger     These conditions exposed employees to hazards of fire and explosion or inhalation of ammonia vapors.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.119 J04 III

Serious Gravity 10 2 instances 2 exposed
Issued
Aug 20, 2013
Abate by
Mar 17, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.119(j)(4)(iii): The frequency of inspections and tests of process equipment to maintain its mechanical integrity, was not consistent with applicable manufacturer's recommendations and good engineering practices, or more frequently determined to be necessary by prior operating experience.        The employer did not ensure the frequency of tests and inspections are consistent with recognized and generally accepted good engineering practices (RAGAGEP) or the manufacturers' recommendations.    A.  The violation occurred in the 38 degree engine room on or about May 8, 2013, and at times prior thereto, where the employer failed to ensure the frequency of inspection and tests of ammonia refrigeration equipment cutouts were inspected and tested annually in accordance with RAGAGEP such as International Institute of Ammonia Refrigeration (IIAR) Bulletin 110. Identified cutouts include but not limited to:             a.    Ammonia Compressor (RC1)         b.    Ammonia Compressor (RC3)      B.  The violation occurred in the 38 degree engine room on or about May 8, 2013, and at times prior thereto, where the employer failed to ensure the external visual inspection of vessels and piping were conducted annually in accordance with RAGAGEP such as International Institute of Ammonia Refrigeration (IIAR) Bulletin 110. Identified vessels include but not limited to:             a.    Accumulator (4)         b.    Accumulator (5)         c.    Surge Drum         d.    Water Heat Exchanger       These conditions exposed employees to hazards of fire and explosion or inhalation of ammonia vapors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.119 J02

Serious Gravity 5 4 instances 4 exposed
Issued
Aug 20, 2013
Abate by
Sep 18, 2013
Penalty
Initial $4,400 · Current $0 Reduced
29 CFR 1910.119(j)(2): The employer did not establish or implement written procedures to maintain the on-going integrity of process equipment.      The employer did not ensure written procedures are established and implemented to maintain the on-going mechanical integrity of process equipment.    A.  The violation occurred in the 38 degree engine room on or about May 8, 2013, and at times prior thereto, where the employer did not ensure detailed written procedures were established and implemented for testing of safety cutouts. Identified cutouts include but not limited to:              a.    Compressor High/Discharge Pressure          b.    Compressor High/Low Oil Differential pressure          c.    Compressor High Discharge Temperature          d.    High/Low Vessel Level.       B.  The violation occurred in the 38 degree engine room on or about May 8, 2013, and at times prior thereto, where the employer did not ensure detailed written procedures were established and implemented for determining locations for conducting thickness measurements of piping and vessels.  These conditions exposed employees to hazards of fire and explosion or inhalation of ammonia vapors.       C.  The violation occurred in the 38 degree engine room on or about May 8, 2013, and at times prior thereto, where the employer did not ensure detailed written procedures were established and implemented for the visual external inspections of insulated piping and vessels.  These conditions exposed employees to hazards of fire and explosion or inhalation of ammonia vapors.       D.  The violation occurred in the 38 degree engine room on or about May 8, 2013, and at times prior thereto, where the employer did not ensure detailed written procedures were established and implemented for the inspection of relief valves and relief vent system(s).  These conditions exposed employees to hazards of fire and explosion or inhalation of ammonia vapors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4400

1910.119 O04

Deleted Serious Gravity 5 2 instances 4 exposed
Issued
Aug 20, 2013
Abate by
Sep 18, 2013
Penalty
Initial $4,400 · Current $0 Reduced
29 CFR 1910.119(o)(4): The employer shall promptly determine and document an appropriate response to each of the findings of the compliance audit and document that deficiencies have been corrected.   On or about May 8, 2013 and times prior thereto, the employer did not ensure the appropriate responses were determined and documented for each of the findings contained in the 2010 Process Safety Management Compliance Audit including but not limited to:  a)    Item number 69  b)    Item number 70   These conditions exposed employees to hazards of fire and explosion or inhalation of ammonia vapors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4400

1910.146 C02

Other-than-serious 1 instance 2 exposed
Issued
Aug 20, 2013
Abate by
Mar 17, 2014
Penalty
Initial $2,805 · Current $2,805
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces.      On or about May 8, 2013, and times prior thereto, below the condenser EC-1, the employer did not ensure a confined space sign was posted exposing the employees to flammable gasses, vapors or potential air contaminants.
Recent events (2)
  • — I (O) $2805
  • — Z (S) $2805

1910.305 G02 II

Other-than-serious 1 instance 2 exposed
Issued
Aug 20, 2013
Abate by
Mar 17, 2014
Penalty
Initial $4,400 · Current $4,400
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap.      On or about May 8, 2013, and times prior thereto, near the condenser EC-1, an extension cord spliced in several places was used to energize a sump pump exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $4400
  • — Z (S) $4400

View Russell Stover Candies, INC.'s full OSHA safety record →