TULLY, NY ·
OSHA Inspection: APPLIED CONCEPTS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of APPLIED CONCEPTS INC. in 397 STATE ROUTE 281, TULLY, NY 13159 (NAICS 334419). OSHA activity number 339056095.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- APPLIED CONCEPTS INC.
- Site address
- 397 STATE ROUTE 281
- City
- TULLY
- State
- NY
- ZIP
- 13159
- Mailing
- PO BOX 1175, TULLY, NY 13159
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334419
- Employees
- 30
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.106 E06 I
- Issued
- May 29, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $1,785 · Current $1,071 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions against the ignition of flammable vapors were not taken: a) Coating Room, on or about 5/14/13: Employees used Class 1B flammable materials: HumiSeal Thinner 73 and HumiSeal 1B73 without grounding the containers.
Recent events (2)
- · I (S) $1071
- · Z (S) $1785
1910.106 E06 II
- Issued
- May 29, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container: a) Coating Room, on or about 5/14/13: Employees dispense Class 1B flammable materials including but not limited to: HumiSeal Thinner 73 and HumiSeal 1B73 to a secondary container with no means of electrically interconnecting the nozzle and the portable container.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A01
- Issued
- May 29, 2013
- Abate by
- Jun 18, 2013
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created point of operation, rotating parts, and flying chips: a) Model Shop, on or about 5/14/13: 299 Enco Drill Press was not provided with a chuck and tool guard.
Recent events (2)
- · I (S) $1428
- · Z (S) $2380
1910.242 B
- Issued
- May 29, 2013
- Abate by
- Jun 13, 2013
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Coating Room, on or about 5/14/13: Employees using compressed air for cleaning purposes was measured at approximately 70 p.s.i.
Recent events (2)
- · I (S) $1428
- · Z (S) $2380
More inspections at Applied Concepts INC.
View Applied Concepts INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334419)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339056095.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.