Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NEXANS ENERGY USA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NEXANS ENERGY USA, INC. in 25 OAKLAND AVE., CHESTER, NY 10918 (NAICS 332618). OSHA activity number 339057747.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nexans Energy USA, INC. — free Get an email when a new federal OSHA severe-injury report for Nexans Energy USA, INC. is published. One employer, no account, unsubscribe in one click.
Site address
25 OAKLAND AVE.
City
CHESTER
State
NY
ZIP
10918
Mailing
25 OAKLAND AVE., CHESTER, NY 10918
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332618
Employees
160
Ownership type
A

3 citations on file for this inspection.

1910.215 B09

Serious Gravity 5 2 instances 10 exposed
Issued
Aug 7, 2013
Abate by
Aug 22, 2013
Penalty
Initial $3,400 · Current $2,550 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  A) Maintenance Shop - On or about May 8, 2013, the United States Electric Tool grinder (Serial #314737) was not equipped with tongue guards on the two abrasive wheels; unguarded opening was approximately 3/4".
Recent events (2)
  • — I (S) $2550
  • — Z (S) $3400

1910.303 B07 I

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 7, 2013
Abate by
Aug 22, 2013
Penalty
Initial $3,400 · Current $2,550 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.  A) Armory Department - On or about May 8, 2013, the Allen Bradley Bulletin 800R switchbox on BX-17 was missing a knockout to block off the opening for the lower switch.
Recent events (2)
  • — I (S) $2550
  • — Z (S) $3400

1910.147 C05 II B

Other-than-serious 1 instance 10 exposed
Issued
Aug 7, 2013
Abate by
Aug 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii)(B): Lockout and tagout devices were not standardized within the facility in at least one of the following criteria: color; shape; or size:  A) Maintenance Shop - On or about May 8, 2013, the lockout devices in the cabinet were not standardized in color, shape, or size.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Nexans Energy USA, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339057747.