ONEIDA, NY ·
OSHA Inspection: ONEIDA CASTING GROUP
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of ONEIDA CASTING GROUP in 559 FITCH STREET, ONEIDA, NY 13421 (NAICS 331511). OSHA activity number 339059248.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ONEIDA CASTING GROUP
- Site address
- 559 FITCH STREET
- City
- ONEIDA
- State
- NY
- ZIP
- 13421
- Mailing
- 559 FITCH STREET, ONEIDA, NY 13421
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331511
- Employees
- 15
- Ownership type
- Private (A)
Citations
15 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 27, 2013
- Abate by
- Nov 1, 2013
- Penalty
- Initial $1,700 · Current $510 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazard of being struck by the load should the load slip off the hook or the lifting device fails. a. Main pour area, on or about 05/16/13: Two Shepard Niles hoists, (units #4 and #5), one P&H hoist, (unit#1), one Cleveland Tramrail hoist, (unit #2) and one Shepard hoist, (unit #5), were being operated without hook throat safety latches. Among other methods, one feasible and acceptable method to correct the hazard is to: Install new safety latches on the lifting hooks in accordance with ANSI B-30.16-1993, section 16-1.2.9. b. Main pour area, on or about 05/16/13: Cleveland Tramrail hoist (unit #2) below-the-hook lifting device was not labeled with its load rating capacity. c. Scrap charge storage area, on or about 05/16/13: Below-the-hook lifting device uses to weigh the charge carts was not labeled with its load rating capacity. Among other methods, one feasible and acceptable method to correct this hazard is to: Mark the rated load lifting capacity on the below-the-hook lifting device in accordance with ASME B30.20-1993, section 20-1.2.1. d. Cupola Area, on or about 05/16/13: A pneumatic powered, hydraulic freight elevator was being used without any hoist way doors/gates. Among other methods, one feasible and acceptable method to correct this hazard is to : Install and/or repair the doors and install interlocks in accordance with ASME A17.3-1993, Safety Code for Existing Elevators and Escalators.
Recent events (3)
- · J (S) $510
- · C (S) $1700
- · Z (S) $1700
1910.23 C01
- Issued
- Sep 27, 2013
- Abate by
- Oct 7, 2013
- Penalty
- Initial $2,000 · Current $600 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floor(s) or platform(s) 4 feet (1.22 m) or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: a. Next to the muller, on or about 05/16/13: Approximately four foot eight inch deep "pit" next tot he muller was not provided with any type of guardrail system. b. Upper conveyor platform, on or about 05/22/13: An approximately four foot section of guardrail system was missing at the conveyor platform. c. In the charging room, on or about 05/16/13: The upper entrance to the cupola was not guarded with any type of guardrail system. d. Access platform to the muller, on or about 05/16/13: The ladder access to the platform was not equipped with any type of guardrail system. e. Platform at top of bucket elevator, one side of the platform was not equipped with a standard guardrail system. f. Upper level of sand conveyor, on or about 05/22/13: Open door on second story was not guarded by a standard railing. Abatement certification must be submitted for these items.
Recent events (3)
- · J (S) $600
- · C (S) $2000
- · Z (S) $2000
1910.24 E
- Issued
- Sep 27, 2013
- Abate by
- Nov 1, 2013
- Penalty
- Initial $1,600 · Current $480 Reduced
General-duty citation text
29 CFR 1910.24(e): Fixed stairs were not installed at angles to the horizontal of between 30 degrees and 50 degrees: a. The stairway leading to the upper level to cupola, on or about 05/16/13: Stairs were installed at approximately 60 degrees to the horizontal. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $480
- · C (S) $1600
- · Z (S) $1600
1910.26 A01 V
- Issued
- Sep 27, 2013
- Abate by
- Nov 1, 2013
- Penalty
- Initial $2,000 · Current $600 Reduced
General-duty citation text
29 CFR 1910.26(a)(1)(v): Rungs and steps were not corrugated, knurled, dimpled, coated with skid-resistant material, or otherwise treated to minimize the possibility of slipping: a. Cupola upper access, on or 05/16/13: The rungs of a chain ladder used to access the cupola were not treated or knurled to minimize the possibility of slipping. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $600
- · C (S) $2000
- · Z (S) $2000
1910.37 A03
- Issued
- Sep 27, 2013
- Abate by
- Oct 7, 2013
- Penalty
- Initial $1,600 · Current $480 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not free and/or unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp were not provided where the exit route was not substantially level. a. At the rear of the facility, on or about 07/31/13: Emergency exit at the rear of the facility was blocked by the cupola spewing molten slag and sparks on a weekly basis. Additionally, the exit in the other direction is blocked by locked cattle fencing. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $480
- · C (S) $1600
- · Z (S) $1600
1910.212 A01
- Issued
- Sep 27, 2013
- Abate by
- Oct 7, 2013
- Penalty
- Initial $2,000 · Current $600 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: a. Squeezer area, on or about 05/16/13: Adjacent to the muller, conveyor system head pulley of the belt created an inrunning nip-point and the "dogs" were not guarded against accidnetal contact. Abatement certification must be submitted for these items.
Recent events (3)
- · J (S) $600
- · C (S) $2000
- · Z (S) $2000
1910.213 I01
- Issued
- Sep 27, 2013
- Abate by
- Oct 7, 2013
- Penalty
- Initial $2,000 · Current $600 Reduced
General-duty citation text
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded: (a) In the maintenance shop, on or about 05/16/13: The non-working portion of the blade on the Delta brand vertical band saw was not guarded against accidental contact. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $600
- · C (S) $2000
- · Z (S) $2000
1910.215 B09
- Issued
- Sep 27, 2013
- Abate by
- Oct 7, 2013
- Penalty
- Initial $1,600 · Current $480 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch. In the grinding department, on or about 05/22/13: The distance from the abrasive wheel on the right side of the grinder to the adjustable tongue guard was three inches. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $480
- · C (S) $1600
- · Z (S) $1600
1910.219 D01
- Issued
- Sep 27, 2013
- Abate by
- Oct 17, 2013
- Penalty
- Initial $1,600 · Current $480 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a. In the squeezer room, on or about 05/16/13: A pulley on the Simpson Mix-Muller was not guarded against accidental contact. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $480
- · C (S) $1600
- · Z (S) $1600
1910.219 E03 I
- Issued
- Sep 27, 2013
- Abate by
- Oct 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a. In the squeezer room, on or about 05/16/13: An inclined belt on the Simpson Mix-Muller was not guarded against accidental contact. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $0
- · C (S) $0
- · Z (S) $0
1910.242 B
- Issued
- Sep 27, 2013
- Abate by
- Oct 7, 2013
- Penalty
- Initial $1,200 · Current $360 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a. In the main pour area, on or about 05/22/13: Compressed air wand operating at approximately 100 p.s.i. used for cleaning was not reduced to below 30 p.s.i. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $360
- · C (S) $1200
- · Z (S) $1200
1910.243 C01
- Issued
- Sep 27, 2013
- Abate by
- Oct 7, 2013
- Penalty
- Initial $1,600 · Current $480 Reduced
General-duty citation text
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4): a. In the grinding room, on nor about 05/22/13: Four held held portable grinders were being operated without safety guards. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $480
- · C (S) $1600
- · Z (S) $1600
1910.303 G02 I
- Issued
- Sep 27, 2013
- Abate by
- Oct 7, 2013
- Penalty
- Initial $1,600 · Current $480 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets of other forms of approved enclosures, or other means listed under this provision: a. Breaker panel in main shop, on or about 05/16/31: Circuit breaker panel had opening in the front where a circuit breaker would be exposing live electrical parts. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $480
- · C (S) $1600
- · Z (S) $1600
1910.305 G01 I
- Issued
- Sep 27, 2013
- Abate by
- Oct 17, 2013
- Penalty
- Initial $1,200 · Current $360 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(i): Flexible cords and cables were not approved or conditions of use and location: a. In the core area, on or about 05/22/13: A flexible cord was used in lieu of permanant wiring when run from an electrical box to the back side of of the oven. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $360
- · C (S) $1200
- · Z (S) $1200
1910.305 G02 III
- Issued
- Sep 27, 2013
- Abate by
- Oct 17, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a. In the core area, on or about 05/22/13: A flexible cord was run from a knockout in a junction box to equipment at the rear of the core oven. The cord was not equipped with any type of strain relief. Abatement certification must be submitted for this item.
Recent events (3)
- · J (S) $0
- · C (S) $0
- · Z (S) $0
More inspections at Oneida Casting Group
View Oneida Casting Group's full OSHA safety record →
More inspections in this industry (NAICS 331511)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339059248.