Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NEW AGE FASTENING SYSTEMS, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of NEW AGE FASTENING SYSTEMS, INC. in 2 ENTERPRISE COURT, SEWELL, NJ 08080 (NAICS 332812). OSHA activity number 339062762.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NEW AGE Fastening Systems, INC. — free Get an email when a new federal OSHA severe-injury report for NEW AGE Fastening Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2 ENTERPRISE COURT
City
SEWELL
State
NJ
ZIP
08080
Mailing
11A ENTERPRISE COURT, SEWELL, NJ 08080
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
21
Ownership type
A

3 citations on file for this inspection.

1910.95 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 9, 2013
Penalty
Initial $1,870 · Current $1,870

Hazardous substances 81108111

29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program:  Full shift noise monitoring was not conducted for the employee with the following exposure:  a) Yard behind shop - An abrasive blaster was exposed to continuous noise levels in excess of the allowable 8 hour time-weighted average sound level (Permissible Level). The employees dosimeter dBA level was 706% of the permissible level (90 dBA) and was equivalent to approximately 104.1 dBA. The sampling was performed for 164 minutes during one shift on 5/22/13. Zero exposure was assumed for the unsampled period of time.
Recent events (1)
  • — Z (S) $1870

1910.95 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 9, 2013
Abate by
Sep 5, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 81108111

29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels:  Audiometric testing was not provided for the employee with the following exposure:  a)  Yard behind shop - An abrasive blaster was exposed to continuous noise levels in excess of the allowable 8 hour time-weighted average sound level (Permissible Level). The employees dosimeter dBA level was 706% of the permissible level (90 dBA) and was equivalent to approximately 104.1 dBA. The sampling was performed for 164 minutes during one shift on 5/22/13. Zero exposure was assumed for the unsampled period of time.   NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $0

1910.95 K01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 9, 2013
Abate by
Sep 5, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 81108111

29 CFR 1910.95(k)(1): The employer did not train each employee who is exposed to noise at or above an 8-hour time-weighted average of 85 decibels in accordance with the requirements of 29 CFR 1910.95(k). The employer did not institute a training program and ensure employee participation in the program:  Noise training was not provided for the employee with the following exposure:  a) Yard behind shop - An abrasive blaster was exposed to continuous noise levels in excess of the allowable 8 hour time-weighted average sound level (Permissible Level). The employees dosimeter dBA level was 706% of the permissible level (90 dBA) and was equivalent to approximately 104.1 dBA. The sampling was performed for 164 minutes during one shift on 5/22/13. Zero exposure was assumed for the unsampled period of time.   NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $0

View NEW AGE Fastening Systems, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339062762.