Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: J.G. LEONE ENTERPRISES INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of J.G. LEONE ENTERPRISES INC. in JOHNSON SHORT RD., QUITMAN, GA 31643 (NAICS 238120). OSHA activity number 339062911.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J.G. Leone Enterprises INC. for free Get an email when a new federal OSHA severe-injury report for J.G. Leone Enterprises INC. is published. One employer, no account, unsubscribe in one click.
Site address
JOHNSON SHORT RD.
City
QUITMAN
State
GA
ZIP
31643
Mailing
3540 BALL GROUND HWY, CANTON, GA 30114
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
7
Ownership type
Private (A)

5 citations on file for this inspection.

1926.251 E08 III

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Aug 23, 2013
Abate by
Sep 19, 2013
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1926.251(e)(8)(iii): Synthetic web sling(s) were not immediatly removed from service when snags, punctures, tears, or cuts were present:  A) Job site, on or about May 7, 2013, a polyester sling with a tear/cut was used to transport a welding machine, exposing employees to a struck by hazard.
Recent events (3)
  • · F (S) $0
  • · C (S) $1600
  • · Z (S) $1600

1926.350 A10

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 23, 2013
Abate by
Sep 23, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinder or combustible materials (especially oil or grease), a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour:    A) Job site, on or about May 7, 2013, Oxygen and Acetylene cylinders were stored approximately 9 feet apart, exposing employees to a fire hazard.
Recent events (3)
  • · F (S) $1600
  • · C (S) $1600
  • · Z (S) $1600

1926.352 D

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Aug 23, 2013
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1926.352(d): Suitable fire extinguishing equipment was not immediately available in the work area(s) where welding, cutting, or heating was being performed:   A)  Job site, on or about May 7, 2013, an employee was cutting steel using oxygen and acetylene without a fire extinguisher immediately available in the area, exposing employees to a fire hazard.
Recent events (3)
  • · F (S) $0
  • · C (S) $1600
  • · Z (S) $1600

1926.1053 B16

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Aug 23, 2013
Abate by
Sep 19, 2013
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:  A) Job site, on or about May 7, 2013, employees used an extension ladder that had a damaged foot and a loose brace under the first rung, exposing employees to a fall hazard
Recent events (3)
  • · F (S) $0
  • · C (S) $1600
  • · Z (S) $1600

1910.1200 E01

Other-than-serious 1 instance 2 exposed
Issued
Aug 23, 2013
Abate by
Sep 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:   A) Job site, on or about May 7, 2013, the employer did not develop a written a hazard communication program for employees who were exposed to hazardous materials such as, but not limited to Oxygen and Acetylene and welding rods exposing employees to burn hazards.
Recent events (3)
  • · F (O) $0
  • · C (O) $0
  • · Z (O) $0

View J.G. Leone Enterprises INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339062911.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.