YONKERS, NY —
OSHA Inspection: CLOVER WIRE FORMING CO. INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of CLOVER WIRE FORMING CO. INC. in 1021 SAW MILL RIVER ROAD, YONKERS, NY 10710 (NAICS 332618). OSHA activity number 339063083.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CLOVER WIRE FORMING CO. INC.
- Site address
- 1021 SAW MILL RIVER ROAD
- City
- YONKERS
- State
- NY
- ZIP
- 10710
- Mailing
- 1021 SAW MILL RIVER ROAD, YONKERS, NY 10710
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332618
- Employees
- 26
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.215 A02
- Issued
- Oct 28, 2013
- Penalty
- Initial $2,800 · Current $600 Reduced
General-duty citation text
29 CFR 1910.215(a)(2): The safety guard did not cover the spindle end, nut, and flange projections. The safety guard was not mounted so as to maintain proper alignment with the wheel, and the strength of the fastenings did not exceed the strength of the guard, except: a) Job Site, East Wall: "Ryobi Pedestal Grinding machine." Serial number BGH6110. A guard was not provided over spindle end of the grinding wheel, on or about 4/30/2013.
Recent events (3)
- — C (S) $2800
- — F (S) $600
- — Z (S) $2800
1910.215 B09
- Issued
- Oct 28, 2013
- Penalty
- Initial $2,800 · Current $600 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, were not constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. a) Job Site, East wall: An adjiustable tongue was not installed on the Baldor pedestal Grinder, on or about 4/30/2013.
Recent events (3)
- — C (S) $2800
- — F (S) $600
- — Z (S) $2800
1910.219 D01
- Issued
- Oct 28, 2013
- Abate by
- Nov 7, 2013
- Penalty
- Initial $2,800 · Current $600 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, were not guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. a) Job Site, Center of Room: "Famco Model 612, Metal Cutting Band Saw". The pulley(s) of the band saw were not provided with a guard, on or about 4/30/2013. b) Job site, center of Room: "Nilson # 2A Wire machine". Inadequate guarding protection was provided over the pulleys; on or about 4/30/2013.
Recent events (3)
- — C (S) $2800
- — F (S) $600
- — Z (S) $2800
1910.219 E03 I
- Issued
- Oct 28, 2013
- Abate by
- Nov 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts were not enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section: a) Job Site, Center of Room: The inclined belt of the "Famco Model 612", metal cutting band saw, was not guarded not guarded, on or about; 4/30/2013. b) Job Site, Center of Room: " Nilson # 2A, wire cutting machine. Inadequate protection was provided over the three inclined belts; on or about 4/30/2013.
Recent events (3)
- — C (S) $0
- — F (S) $0
- — Z (S) $0
1910.303 G02 I
- Issued
- Oct 28, 2013
- Penalty
- Initial $3,500 · Current $842 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means: a) Job Site, Center of Room: "Nilson Number 326-H-W". The electrical panel of the welder machine was not provided with a cover; on or about 4/30/2013:
Recent events (3)
- — C (S) $3500
- — F (S) $842
- — Z (S) $3500
1910.304 B03 II C 3
- Issued
- Oct 28, 2013
- Penalty
- Initial $2,100 · Current $500 Reduced
General-duty citation text
29 CFR 1910.304(b)(3)(ii)(C)(3): Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, were not visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. a) Job Site, West Wall: The electrical cord for a Demagnetizer machine had missing a 1/4" of the outer insulation; on or about 4/30/2013. b) Job Site, West Area: The electrical cord supplying power to the welder machine, had missing 1/2" of the outer insulation; on or about 4/30/2013.
Recent events (3)
- — C (S) $2100
- — F (S) $500
- — Z (S) $2100
1910.305 B01 II
- Issued
- Oct 28, 2013
- Penalty
- Initial $3,500 · Current $842 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed. a) Job Site, West Wall, Panel #5: A circuit breaker panel had three openings that were missing either breakers or blanks, on or about 4/30/2013.
Recent events (3)
- — C (S) $3500
- — F (S) $842
- — Z (S) $3500
More inspections at Clover Wire Forming CO. INC.
View Clover Wire Forming CO. INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332618)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339063083.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.