OSHA Inspection: R. L. ZEIGLER CO., INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of R. L. ZEIGLER CO., INC. in 1 PLANT STREET, SELMA, AL 36702 (NAICS 311612). OSHA activity number 339063315.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R. L. Zeigler CO., INC. — free Get an email when a new federal OSHA severe-injury report for R. L. Zeigler CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
1 PLANT STREET
City
SELMA
State
AL
ZIP
36702
Mailing
P. O. BOX 367, SELMA, AL 36702
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311612
Employees
180
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 18, 2013
Abate by
Aug 6, 2013
Penalty
Initial $3,251 · Current $2,000 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section  (a) Facility Wide: May 8, 2013: the employer did not ensure that the written Lock Out Tag Out (LOTO) procedures had clear, specific and correct steps needed to isolate and secure the pneumatic energy sources used for the In Line Screw Feed.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3251

1910.147 D04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 18, 2013
Abate by
Aug 6, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) Facility Wide: On or about May 8, 2013: the employer did not provide a sufficient number of locks to lock-out all energy sources for employees required to lock-out equipment with more than one energy source during night shift sanitation operations.