UTICA, NY —
OSHA Inspection: MAJIC CONSTRUCTION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MAJIC CONSTRUCTION in 514 MILGATE STREET, UTICA, NY 13501 (NAICS 237110). OSHA activity number 339064933.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAJIC CONSTRUCTION
- Site address
- 514 MILGATE STREET
- City
- UTICA
- State
- NY
- ZIP
- 13501
- Mailing
- 223 RUTGER STREET, UTICA, NY 13501
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.651 J01
- Issued
- Jun 27, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.651(j)(1): Adequate protection was not provided to protect employees from loose rock or soil that could pose a hazard by falling or rolling from an excavation face: a) East side of excavation, on or about 5-9-13: Two employees were working in an excavation with large asphalt, concrete, and curb sections at the immediate edge of the excavation.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.651 J02
- Issued
- Jun 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection by placing and keeping such materials or equipment at least 2 feet from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary was not provided: a) East side of building, on or about 5-9-13: Two employees were working in an excavation, 7 feet deep, with spoil materials piled at the immediate edge of the excavation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.652 A01
- Issued
- Jun 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c): a) East side of building, on or about 5-9-13: Two employees were working in an excavation, 7 feet deep, without an adequate protective system in place.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.651 B04
- Issued
- Jun 27, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.651(b)(4): While the excavation was opened, underground installations were not protected, supported or removed as necessary to safeguard employees: a) East side of building, on or about 5-9-13: Two employees were working in an excavation, 7 feet deep, where a natural gas line was not protected or supported.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.651 K
- Issued
- Jun 27, 2013
- Abate by
- Jul 12, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k): Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated: a) East side of building, on or about 5-9-13: Two employees were working in an excavation, 7 feet deep, that was not inspected by a competent person.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Majic Construction
View Majic Construction's full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339064933.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.