Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COSMOS COMPREHENSIVE CONSTRUCTION, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of COSMOS COMPREHENSIVE CONSTRUCTION, INC. in TRABUE ROAD AT I-270 -- BRIDGE FRA-270-0930, COLUMBUS, OH 43228 (NAICS 238320). OSHA activity number 339065096.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cosmos Comprehensive Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Cosmos Comprehensive Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
TRABUE ROAD AT I-270 -- BRIDGE FRA-270-0930
City
COLUMBUS
State
OH
ZIP
43228
Mailing
816 MILAN STREET, N., CANAL FULTON, OH 44614
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
8
Ownership type
A

2 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 7, 2013
Abate by
Jun 7, 2013
Penalty
Initial $2,678 · Current $1,875 Reduced
29 CFR 1926.404(b)(1)(ii):  Ground-fault circuit interrupters.  All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection.  Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters:   a. At the job site for bridge FRA-270-0930, the upper duplex receptacle outlet energized by the 30 kW Magnetek Genesis generator (model: RD370) located on the Advanced Recycling System (model ARIESVAC) did not have a ground-fault circuit interrupter (GFCI) for employee protection.
Recent events (2)
  • — I (S) $1874.6
  • — Z (S) $2678

1926.404 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 7, 2013
Abate by
Jun 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):  Grounding path.  The path to ground from circuits, equipment, and enclosures shall be permanent and continuous:   a. At the job site for bridge FRA-270-0930, an extension cord which was plugged into the lower duplex receptacle outlet energized by the 30 kW Magnetek Genesis generator (model: RD370) and used to supply power to the pulsator on the Ingersoll-Rand dust collector (model: DC24) did not have a ground prong.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Cosmos Comprehensive Construction, INC.'s full OSHA safety record →