COVINGTON, GA —
OSHA Inspection: STAMPTECH, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of STAMPTECH, INC. in 40 PINYON RD, COVINGTON, GA 30016 (NAICS 332111). OSHA activity number 339065716.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STAMPTECH, INC.
- Site address
- 40 PINYON RD
- City
- COVINGTON
- State
- GA
- ZIP
- 30016
- Mailing
- 40 PINYON RD, COVINGTON, GA 30014
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332111
- Employees
- 22
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jul 12, 2013
- Abate by
- Aug 28, 2013
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a)Production Area-Authorized employees were exposed to unexpected energy start up hazards on or about 5/10/13. The employer did not develop and implement procedures for each piece of equipment. The authorized employees are required to set up, perform maintenance, and make repairs on the following machines: a) Mazak Hypergear Laser b) Finn Power C6 Turret c) Finn Power C5 Turret d) Finn Power F6 Turret e) Amada HDS 220 Press f) Amada HD 130 Press g) Amada HDS 130 Press h) Donaldson Dust Collector In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1910.147 C07 I
- Issued
- Jul 12, 2013
- Abate by
- Aug 28, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: (a) Authorized employees were exposed to unexpected energy start-up hazards on or about 5/10/13. Operators required to set up the equipment were not trained on the authorized level. Equipment includes, but is not limited to: a.Mazak Hypergear Laser b.Finn Power C6 Turret c.Finn Power C5 Turret d.Finn Power F6 Turret e.Amada HDS 220 Press f.Amada HD 130 Press g.Amada HDS 130 Press h.Donaldson Dust Collector
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- Jul 12, 2013
- Abate by
- Jul 22, 2013
- Penalty
- Initial $2,040 · Current $1,224 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a)Production Area-Employees were exposed to burn hazards in that the fire extinguishers in the weldng area were not mounted on or about 5/10/13. (b)Production Area-Employees were exposed to burn hazards in that the fire extinguisher in the power press area was not mounted on or about 5/10/13. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1224
- — Z (S) $2040
1910.157 G01
- Issued
- Jul 12, 2013
- Abate by
- Aug 7, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: (a) Employees in the welding area that are expected to fight fires had not been trained on or about 5/10/13. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Stamptech, INC.
View Stamptech, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332111)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339065716.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.