Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRETIUM PACKAGING, L.L.C.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRETIUM PACKAGING, L.L.C. in 4444 HOLLERICH BLVD., PERU, IL 61354 (NAICS 326199). OSHA activity number 339065971.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pretium Packaging, L.L.C. — free Get an email when a new federal OSHA severe-injury report for Pretium Packaging, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
4444 HOLLERICH BLVD.
City
PERU
State
IL
ZIP
61354
Mailing
4444 HOLLERICH BLVD., PERU, IL 61354
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
31
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 17, 2013
Abate by
Jul 20, 2013
Penalty
Initial $2,618 · Current $1,309 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     (a) Maintenance dept. On or about May 14, 2013, Kalamazoo belt sanding machine was not guarded at the ingoing nip point where the sanding belt runs onto the bottom pulley. The unused sanding belt runs of the belt sanding machine were not guarded against accidental contact.     Abatement certification is required of this item in accordance with the requirements of 1903.19(c).
Recent events (2)
  • — I (S) $1309
  • — Z (S) $2618

1910.303 G01

Serious Gravity 5 2 instances 3 exposed
Issued
Jun 17, 2013
Abate by
Jul 20, 2013
Penalty
Initial $3,273 · Current $1,637 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    (a) Line 1. On or about May 14, 2013, employees were not able to safely access the DP4 480V electrical panel obstructed by a packing machine when needed.     (b) Old Docks. On or about May 14, 2013, employees were not able to safely access the 480V electrical panel obstructed by stored materials when needed.     Abatement certification is required of this item in accordance with the requirements of 1903.19(c).
Recent events (2)
  • — I (S) $1636.5
  • — Z (S) $3273

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 17, 2013
Penalty
Initial $2,618 · Current $1,309 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) Warehouse loading docks. On or about May 14, 2013, employees were exposed to electric shock hazards where live electrical components in the circuit breaker were not covered at the opening.     There is no abatement certification or documentation required for this item.
Recent events (2)
  • — I (S) $1309
  • — Z (S) $2618

1910.219 C04 I

Deleted Other-than-serious 1 instance 2 exposed
Issued
Jun 17, 2013
Abate by
Jul 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft ends did not present a smooth edge and end and projected more than one half the diameter of the shaft:  (a) Production dept., Line 1 and Line 2. On or about May 14, 2013, employees conducting bottles quality checks and metal detector testing were exposed to caught-on hazards where rotating ends of the projecting shafts were not guarded to prevent accidental contact.  Abatement certification is required of this item in accordance with the requirements of 1903.19(c).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Pretium Packaging, L.L.C.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339065971.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.