OSHA Inspection: ROCKY MOUNTAIN AIR AND LUBRICATION, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of ROCKY MOUNTAIN AIR AND LUBRICATION, INC. in 2244 MAIN, BILLINGS, MT 59105 (NAICS 811310). OSHA activity number 339070013.

Watch Rocky Mountain AIR AND Lubrication, INC. — free Get an email when a new federal OSHA severe-injury report for Rocky Mountain AIR AND Lubrication, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2244 MAIN
City
BILLINGS
State
MT
ZIP
59105
Mailing
2244 MAIN, BILLINGS, MT 59105
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
20
Ownership type
A

5 citations on file for this inspection.

1910.107 G02

Serious Gravity 5 1 instance 9 exposed
Issued
May 22, 2013
Abate by
Jun 18, 2013
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:  (a) Paint Booth: On or about 16 May 2013 and at times prior the paint spray area was not kept as free as practical from accumulation of paint deposits: DuPont "Tufcots" Topcoats and Primers containing Toluene and Xylene are used.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.134 C01

Serious Gravity 1 1 instance 9 exposed
Issued
May 22, 2013
Abate by
Jun 18, 2013
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  (a) Shop: On or about 16 May 2013 and at times prior thereto, when the employer required employees to wear a respirator such as but not limited to a North 7700 half-face respirator with organic cartridges or a 3M 6300 half-face respirator with organic cartridges, the employer did not ensure employees were provided with and/or implement an effective written respirator program that included the following provisions:  1.  The employees had not been medically evaluated to wear a respirator.  2.  The employees had not been annually fit tested on the tight fitting respirators.   3.  Correct procedures for Maintenance and Care of respirators.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.151 C

Serious Gravity 5 1 instance 9 exposed
Issued
May 22, 2013
Abate by
May 22, 2013
Penalty
Initial $2,400 · Current $1,680 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  (a) Dip Tank Area: On or about 1 April 2013 and at times prior the employer did not provide a working eye wash station near the dip tank that contains an 11.0 pH solution of  Sodium Hydroxide used to clean equipment prior to repair.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2400

1910.107 G07

Other-than-serious 1 instance 9 exposed
Issued
May 22, 2013
Abate by
Jun 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(7): "No Smoking" signs. "No smoking" signs in large letters on contrasting color background shall be conspicuously posted at all spraying areas and paint storage rooms.  (a) Paint Booth Area: On or about 16 May 2013 and at times prior the Company had not posted "No Smoking" signs in the paint spraying area.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 9 exposed
Issued
May 22, 2013
Abate by
Jun 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1):   The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a) Shop: On or about 16 May 2013 and at times prior the Employer did not maintain a written Hazard Communication Program; the employer uses chemicals including but not limited to: GF Clean 443 (Sodium Hydroxide) and 61003 Multi-Coat Blank Aerosol (Acetone, Propane)