BATON ROUGE, LA —
OSHA Inspection: WASKEY BRIDGES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WASKEY BRIDGES, INC. in 2651 N. FLANNERY RD, BATON ROUGE, LA 70814 (NAICS 327390). OSHA activity number 339070179.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WASKEY BRIDGES, INC.
- Site address
- 2651 N. FLANNERY RD
- City
- BATON ROUGE
- State
- LA
- ZIP
- 70814
- Mailing
- 2651 N. FLANNERY RD, BATON ROUGE, LA 70814
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327390
- Employees
- 66
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C04 II
- Issued
- Jun 27, 2013
- Abate by
- Jul 17, 2013
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, items (a) through (d) of this section. 1) On or about 05/16/2013, The employer failed to establish clear and specific energy control procedures that outline the scope, purpose, name(s) of person(s) authorized to perform or participate in lock-out/tag-out, and specific techniques to be utilized for the Con-E-Co batch plant located on the southwest side of the yard, which include the following: (1) specific steps for shutting down, isolating, blocking, and securing machines/equipment; (2) Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and (3) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
Recent events (3)
- — F (S) $0
- — C (S) $3500
- — Z (S) $3500
More inspections at Waskey Bridges, INC.
View Waskey Bridges, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327390)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339070179.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.