NORTH BABYLON, NY ·
OSHA Inspection: ANRON SHEET METAL CORP.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ANRON SHEET METAL CORP. in 440 WYANDANCH AVE, NORTH BABYLON, NY 11704 (NAICS 333415). OSHA activity number 339071953.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANRON SHEET METAL CORP.
- Site address
- 440 WYANDANCH AVE
- City
- NORTH BABYLON
- State
- NY
- ZIP
- 11704
- Mailing
- 440 WYANDANCH AVE, NORTH BABYLON, NY 11704
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 35
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Oct 29, 2013
- Abate by
- Dec 17, 2013
- Penalty
- Initial $4,900 · Current $3,920 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Workplace- The employer did not develop or utilize energy control procedures such as Lock Out/ Tag Out device application for the dissipation of energy and verification of isolation on machines such as, but not limited to the Pacific Hydraulic Press Shear, model, J110-12H, serial # A550 and Chicago Dries and Krump, model 1012-B, serial #L-167786 and Engel Industries Lockformer Machine, model # 800-S, serial #3101-86; on or about 5/16/13. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $3920
- · Z (S) $4900
1910.147 C07 I
- Issued
- Oct 29, 2013
- Abate by
- Dec 17, 2013
- Penalty
- Initial $4,900 · Current $3,920 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a) Workplace, Ductwork Production Area- Employees who perform die changes and adjustments on machines such as the Pacific Hydraulic Press Shear, model J110-12H, serial #A550 and the Chicago Dries and Krump Press, model 1012-R, serial # 167L86 and, Engel Industries Lockformer, model #800-5, serial #3101-86 did not receive Lockout/Tagout training; on or about 5/16/13. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $3920
- · Z (S) $4900
1910.304 F01 IV
- Issued
- Oct 29, 2013
- Penalty
- Initial $3,500 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel: a) Workplace, Ductwork Production Area- circuit breaker boxes on east wall, housing power to the production area including, but not limited to warehouse lights, press brake machines, plasma cutting machine and roll forming machine was blocked by an approximately 4'x7' Liner Cutter Machine; on or about 5/16/13. b) Workplace, Ductwork Production Area- circuit breaker box in center of production area housing power including, but not limited to warehouse lights and roll forming machines was blocked by a TDC Roll Former Machine; on or about 5/16/13. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- · I (S) $2800
- · Z (S) $3500
More inspections at Anron Sheet Metal Corp.
View Anron Sheet Metal Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 333415)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339071953.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.