Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: SCHNEIDER ELECTRIC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SCHNEIDER ELECTRIC in 5735 COLLEGE CORNER PIKE, OXFORD, OH 45056 (NAICS 335999). OSHA activity number 339072274.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Schneider Electric for free Get an email when a new federal OSHA severe-injury report for Schneider Electric is published. One employer, no account, unsubscribe in one click.
Establishment
SCHNEIDER ELECTRIC
Site address
5735 COLLEGE CORNER PIKE
City
OXFORD
State
OH
ZIP
45056
Mailing
5735 COLLEGE CORNER PIKE, OXFORD, OH 45056
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335999
Employees
280
Ownership type
Private (A)

5 citations on file for this inspection.

1910.147 C06 I

Deleted Serious Gravity 5 1 instance 30 exposed
Issued
Aug 26, 2013
Abate by
Oct 11, 2013
Penalty
Initial $3,750 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  The periodic inspection conducted by the company within the last year did not include a review of all the specific energy control procedures and a review with all authorized employees on their responsibilities to the Lockout/Tagout Program.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3750

1910.178 G02

Deleted Serious Gravity 1 1 instance 5 exposed
Issued
Aug 26, 2013
Abate by
Sep 13, 2013
Penalty
Initial $3,000 · Current $0 Reduced
29 CFR 1910.178(g)(2): Facilities shall be provided for flushing and neutralizing spilled electrolyte, for fire protection, for protecting charging apparatus from damage by trucks, and for adequate ventilation for dispersal of fumes from gassing batteries.  In the Fabrication 581 Section of the Production Area, a Hobart/Accu Battery Charger for a Stand up and other forklifts in the area was located next to the main aisleway and subject to damage by forklift and other vehicle traffic.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3000

1910.212 A02

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 26, 2013
Penalty
Initial $2,250 · Current $1,500 Reduced
29 CFR 1910.212(a)(2): General requirements for machine guards. Guards shall be affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall be such that it does not offer an accident hazard in itself.    In the Fabrication Department onn the Komatsu P16501 150 Ton Hydraulic Power Press, an adjustable solid metal guard on the end where the sheet metal is fed through to the die was secured by two levers and without the use of a tool to remove and adjust.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2250

1910.217 D01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 26, 2013
Penalty
Initial $7,000 · Current $4,000 Reduced
29 CFR 1910.217(d)(1)(i): Use dies and operating methods designed to control or eliminate hazards to operating personnel; and    On or about April 8, 2013, a Press Operator was struck by a piece of metal from a die insert on a S2-15 P15002 150 Ton Rousselle Mechanical Power Press due to the inadequate secure mechanism on the die insert to prevent a misalignment of the die during a press stroke.
Recent events (2)
  • · I (S) $4000
  • · Z (S) $7000

1910.147 C05 II

Other-than-serious 1 instance 1 exposed
Issued
Aug 26, 2013
Abate by
Sep 6, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices shall be singularly identified; shall be the only devices(s) used for controlling energy; shall not be used for other purposes; and shall meet the following requirements:  On or about April 30, 2013, a Group Leader employee had put his lock on a Bliss P06024 60 Ton Mechanical Power Press to prevent other operators from using the press and not for servicing and maintenance activities under lockout.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Schneider Electric's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339072274.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.