BLOOMINGDALE, NJ ·
OSHA Inspection: ENERGY BEAMS CUSTOM MACHINING
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ENERGY BEAMS CUSTOM MACHINING in 185 HAMBURG TPK, BLOOMINGDALE, NJ 07403 (NAICS 332710). OSHA activity number 339076028.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ENERGY BEAMS CUSTOM MACHINING
- Site address
- 185 HAMBURG TPK
- City
- BLOOMINGDALE
- State
- NJ
- ZIP
- 07403
- Mailing
- 185 HAMBURG TPK, BLOOMINGDALE, NJ 07403
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 12
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Jul 25, 2013
- Abate by
- Sep 11, 2013
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) Machine Shop Area: The employer did not have specific procedural steps for controlling hazardous energy on equipment, such as but not limited to Doosan CNC milling machines, Hipley and Bullard lathes while performing servicing and maintenance, on or about 4/13/2013.
Recent events (2)
- · I (S) $1200
- · Z (S) $2000
1910.147 C06 I
- Issued
- Jul 25, 2013
- Abate by
- Sep 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Machine Shop Area: The employer did not conduct a periodic inspection of the company's energy control procedures, on or about 5/06/2013.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 332710)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339076028.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.