TINTON FALLS, NJ ·
OSHA Inspection: LIMAC COMMUNICATION, LLC
Foreign inspection · Safety discipline
At a glance
On , OSHA opened a foreign safety inspection of LIMAC COMMUNICATION, LLC in 108 KNOLLWOOD DRIVE, TINTON FALLS, NJ 07724 (NAICS 517919). OSHA activity number 339076481.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LIMAC COMMUNICATION, LLC
- Site address
- 108 KNOLLWOOD DRIVE
- City
- TINTON FALLS
- State
- NJ
- ZIP
- 07724
- Mailing
- 107 CHEFIELD COURT, DOUGLASSVILLE, PA 19518
What kind of inspection was it?
- Inspection type
- Foreign (L)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 517919
- Employees
- 8
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.268 C
- Issued
- Aug 22, 2013
- Abate by
- Sep 18, 2013
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1910.268(c): The employer did not prepare employee training certification records which included the identity of the person trained, the signature of the employer or the person who conducted the training, and the date the training was completed: a) Knollwood Drive and Riverdale Avenue, Tinton Falls, NJ 07724: On or about May 14, 2013, the employer failed to certify that each employee was trained in the recognition, avoidance and mitigation of the hazards associated with telecommunications work. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- · Z (S) $2400
1910.268 C03
- Issued
- Aug 22, 2013
- Abate by
- Sep 18, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.268(c)(3): Training provided did not include first aid training, including instruction in artificial respiration: a) Knollwood Drive and Riverdale Avenue, Tinton Falls, NJ 07724: On or about May 14, 2013, the employer failed to ensure that each employee engaged in telecommunications work was trained in first aid. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- · Z (S) $2000
1910.268 E
- Issued
- Aug 22, 2013
- Abate by
- Aug 28, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.268(e): Personal protective equipment, protective devices, and special tools needed for the work of employees were not provided and/or the employer did not ensure that they were used by employees: a) Knollwood Drive and Riverdale Avenue, Tinton Falls, NJ 07724: On or about May 14, 2013, employees were not provided with adequate protective devices and special tools needed for the work. An employee sustained an electrical shock while working in the vacinity of energized overhead powerlines and telecommunication lines of varying potentials. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- · Z (S) $2800
1910.268 F01
- Issued
- Aug 22, 2013
- Abate by
- Aug 28, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.268(f)(1): The employer did not provide rubber insulating equipment designed for the voltage levels to be encountered and/or did ensure that the equipment was used by employees as required by this section: a) Knollwood Drive and Riverdale Avenue, Tinton Falls, NJ 07724: On or about May 14, 2013, employees were not provided with rubber insulated gloves, blankets, nor any other rubber insulated equipment. Employees were working in the vacinity of energized overhead powerlines and telecommunication lines of varying potentials. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- · Z (S) $2800
More inspections in this industry (NAICS 517919)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339076481.