Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CONNECTICUT SCRAP, L.L.C.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CONNECTICUT SCRAP, L.L.C. in 33 PEQUOT ROAD, UNCASVILLE, CT 06382 (NAICS 423930). OSHA activity number 339080665.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Connecticut Scrap, L.L.C. — free Get an email when a new federal OSHA severe-injury report for Connecticut Scrap, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
33 PEQUOT ROAD
City
UNCASVILLE
State
CT
ZIP
06382
Mailing
140 ROUTE 32, NORTH FRANKLIN, CT 06254
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
15
Ownership type
A

12 citations on file for this inspection.

1910.23 C03

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 23, 2013
Abate by
Sep 9, 2013
Penalty
Initial $1,360 · Current $680 Reduced
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board.   Scrap Shredder:  On, or about, May 24, 2013, a midrail was not provided on the shaker table catwalk located over the chute leading to the over-size belt.
Recent events (3)
  • — C (S) $1360
  • — F (S) $680
  • — Z (S) $1360

1910.24 E

Serious Gravity 1 1 instance 5 exposed
Issued
Jul 23, 2013
Abate by
Sep 9, 2013
Penalty
Initial $1,020 · Current $510 Reduced
29 CFR 1910.24(e): Fixed stairs did not have a uniform combination of rise/tread dimensions:   Scrap Shredder:  On, or about, May 24, 2013, adequate access was not provided to the Aluminum Belt Picking Station in that employees had to step up onto a concrete block and then up a metal step to walk across to the picking station.
Recent events (3)
  • — C (S) $1020
  • — F (S) $510
  • — Z (S) $1020

1910.178 A04

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 23, 2013
Abate by
Sep 9, 2013
Penalty
Initial $1,360 · Current $680 Reduced
29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval.  Capacity, operation, and maintenance plates, tags or decals of the powered industrial truck were not changed accordingly:   Maintenance Shop Yard:  On, or about, May 22, 2013, the CAT forktruck, serial number AT87A01366, was provided with eight foot long forks.  The identification plate mounted on the vehicle showed a load capacity based on four foot long forks.
Recent events (3)
  • — C (S) $1360
  • — F (S) $680
  • — Z (S) $1360

1910.303 B07 IV

Serious Gravity 5 2 instances 8 exposed
Issued
Jul 23, 2013
Penalty
Initial $1,360 · Current $680 Reduced
29 CFR 1910.303(b)(7)(iv): There were damaged parts that adversely affected safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:   Processing Facility:  On, or about, May 22, 2013, electrical outlets in the following locations had broken components:  A.     Scotty Shear Work Area:  The cover and lower, right receptacle housing was broken on a live outlet.    B.     Boiler Room:  The cover was broken on a live, wall mounted duplex outlet.
Recent events (3)
  • — C (S) $1360
  • — F (S) $680
  • — Z (S) $1360

1910.303 G01 II

Serious Gravity 5 4 instances 10 exposed
Issued
Jul 23, 2013
Abate by
Sep 9, 2013
Penalty
Initial $1,360 · Current $680 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   On, or about, May 22, 2013, items were stored in the working space in front of panelboards:  A.      Maintenance Shop, Lower East Container Storage:  A Siemens circuit breaker box located at the back of the container was blocked by buckets, wood, a fan and pane of vehicle glass.    B.     Processing Facility, Off-Loading Bay:  A concrete barrier had been placed in front of the Murray circuit breaker box and the GE circuit breaker box to protect them from vehicular damage.  C.      Processing Facility, Plasma Cutting Work Area:  Shelving had been installed under and around the GE circuit breaker box.  D.     Processing Facility, Boiler Room:  A barrel of soap, pressure washing unit and shelving was located in front of and on the side of the GE circuit breaker box.
Recent events (3)
  • — C (S) $1360
  • — F (S) $680
  • — Z (S) $1360

1910.304 A02

Serious Gravity 5 2 instances 3 exposed
Issued
Jul 23, 2013
Abate by
Sep 9, 2013
Penalty
Initial $1,360 · Current $680 Reduced
29 CFR 1910.304(a)(2): Grounded conductors were attached to terminals or leads so as to reverse designated polarity:   On, or about, May 22, 2013, receptacles were found to have reversed polarity when tested:  A.      Maintenance Shop:  Receptacle located near front of shop in the east corner.  B.     Lower East Container Storage Area:  Front of container.
Recent events (3)
  • — C (S) $1360
  • — F (S) $680
  • — Z (S) $1360

1910.305 J02 VII

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 23, 2013
Abate by
Sep 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(vii): A receptacle installed in a wet location where the product intended to be plugged into it was to be attended while in use (for example, portable tools) did not have an enclosure that was weatherproof when the attachment plug cap was removed:   Maintenance Shop:  On, or about, May 22, 2013, a weather cover was not installed on the receptacle located at the front of the shop in the east corner.
Recent events (3)
  • — C (S) $0
  • — F (S) $0
  • — Z (S) $0

1910.304 B03 II A

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 23, 2013
Penalty
Initial $1,700 · Current $850 Reduced
29 CFR 1910.304(b)(3)(ii)(A): All 125-volt, single-phase, 15, 20 and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel did not have ground-fault circuit-interrupter protection for personnel:   Maintenance Shop:  Ground Fault Circuit Interrupter (GFCI) protection was not provided where portable tools such as a wet/dry vacuum and portable tools were energized using the Miller Bobcat generator powered welding unit.
Recent events (3)
  • — C (S) $1700
  • — F (S) $850
  • — Z (S) $1700

1910.27 B01 II

Other-than-serious 1 instance 5 exposed
Issued
Jul 23, 2013
Abate by
Sep 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.27(b)(1)(ii): The distance between rungs, cleats, and steps exceedes 12 inches:     Scrap Shredder:  On, or about, May 24, 2013, the rungs provided on the Trash Belt Picking Station platform access ladder were spaced sixteen inches apart.
Recent events (3)
  • — C (O) $0
  • — F (O) $0
  • — Z (O) $0

1910.178 P01

Other-than-serious 2 instances 5 exposed
Issued
Jul 23, 2013
Abate by
Sep 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):   On, or about, May 22, 2013, the following forktrucks had weather covers secured to the overhead guard that obstructed the operator's view through the guard:  A.      Maintenance Shop Yard:  CAT forktruck, serial number AT87A01366.  B.     Processing Facility Loading Dock:  Toyota forktruck.
Recent events (3)
  • — C (O) $0
  • — F (O) $0
  • — Z (O) $0

1910.1200 F05 I

Other-than-serious 1 instance 7 exposed
Issued
Jul 23, 2013
Abate by
Sep 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:  Processing Facility Loading Dock:  On, or about, May 22, 2013, a fuel storage tank provided for the generator was not labeled with the identity of the contents.  The tank contained diesel fuel, a Category 3 flammable liquid.
Recent events (3)
  • — C (O) $0
  • — F (O) $0
  • — Z (O) $0

1910.1200 F05 II

Other-than-serious 1 instance 7 exposed
Issued
Jul 23, 2013
Abate by
Sep 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:  Processing Facility Loading Dock:  On, or about, May 22, 2013, a fuel storage tank provided for the generator was not labeled with the appropriate hazard warnings.  The tank contained diesel fuel, a Category 3 flammable liquid.
Recent events (3)
  • — C (O) $0
  • — F (O) $0
  • — Z (O) $0