Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: PROFESSIONAL CRYOGENIC METALLURGY & COATING, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PROFESSIONAL CRYOGENIC METALLURGY & COATING, LLC in 5166 PERFORMANCE DRIVE, CUMMING, GA 30040 (NAICS 332812). OSHA activity number 339084196.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Professional Cryogenic Metallurgy & Coating, LLC for free Get an email when a new federal OSHA severe-injury report for Professional Cryogenic Metallurgy & Coating, LLC is published. One employer, no account, unsubscribe in one click.
Site address
5166 PERFORMANCE DRIVE
City
CUMMING
State
GA
ZIP
30040
Mailing
5166 PERFORMANCE DRIVE, CUMMING, GA 30040
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
10
Ownership type
A

9 citations on file for this inspection.

1910.107 H12

Serious Gravity 10 2 instances 10 exposed
Issued
Nov 19, 2013
Abate by
Feb 3, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.107(h)(12): Electrostatic spray area(s) were not provided with automatic sprinkler protection or other approved automatic extinguishing equipment:   On or about 5/21/2013 at 5166 Performance Drive, Cumming, GA:   a) Powder Coating Booth #1-The booth used for powder coating metal parts did not have a sprinkler system or other approved automatic extinguishing equipment.   b) Powder Coating Booth #2-The booth used for powder coating metal parts did not have a sprinkler system or other approved automatic extinguishing equipment.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.107 L02 I

Deleted Serious Gravity 10 2 instances 7 exposed
Issued
Nov 19, 2013
Abate by
Dec 16, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.107(l)(2)(i): All non-deposited air-suspended powder was not safely removed via exhaust ducts to the powder recovery cyclone or receptacle.    On or about 5/21/2013 at 5166 Performance Drive, Cummings, Georgia: Dust classified as combustible is exhausted back into the working area and collected on the equipment, working surfaces, structural members of the building, walls and floor. Employees working in the area are exposed to an explosion hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1910.107 L04 I

Serious Gravity 10 1 instance 10 exposed
Issued
Nov 19, 2013
Abate by
Feb 3, 2014
Penalty
Initial $0 · Current $1,680
29 CFR 1910.107(l)(4)(i): All areas were not kept free of the accumulation of powder coating dust:    On or about 5/21/2013 at 5166 Performance Drive, Cumming, GA: Production Area-Employees were exposed to a fire hazard in that powder coating dust, classified as combustible, was allowed to settle on walls, ledges, beams, pipes and floors.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $0

1910.107 L04 II

Serious Gravity 10 1 instance 9 exposed
Issued
Nov 19, 2013
Abate by
Feb 3, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.107(l)(4)(ii): Surfaces were not cleaned in such a manner as to avoid scattering dust to other places or creating dust clouds.   On or about 05/21/2013 5166 Performance Drive, Cumming, GA: When working surfaces, structural members and structural supports of the building 5166 were to be cleaned, the employees used compressed air, nylon/straw bristle brooms, and a Shop Vac to clean with. The employees were exposed to an explosive atmosphere from the dust cloud created during cleaning.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.178 C02 VI A

Serious Gravity 10 1 instance 8 exposed
Issued
Nov 19, 2013
Abate by
Feb 3, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.178(c)(2)(vi)(a): The employer did not provide powered industrial trucks designated as EX for use in an atmosphere in which combustible dust is or may be in suspension continuously, intermittently, or periodically under normal operating conditions, in quantities sufficient to produce explosive or ignitable mixtures, or where mechanical failure or abnormal operation of machinery or equipment might cause such mixtures to be produced.   On or about May 21, 2013 at 5166 Performance Drive, Cumming GA: Employees operating the Yale forklift were exposed to an explosive hazard when the forklifts used were not designated for use in atmospheres in which combustible dust is present.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.178 L04 III

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 19, 2013
Abate by
Dec 16, 2013
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years.    On or about May 21, 2013, at 5166 Performance Drive, Cumming, GA: Employees that were allowed to operate forklifts in the workplace were not retrained every three years.
Recent events (2)
  • · I (S) $720
  • · Z (S) $1200

1910.178 M03

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 19, 2013
Abate by
Dec 16, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.178(m)(3): A safe place to ride was not provided where riding a powered industrial truck(s) was authorized.  On or about May 21, 2013 at 5166 Performance Drive, Cumming GA: Employees are exposed to a fall hazard in excess of 20 feet when they are lifted on the forks to change light bulbs.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.242 B

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 19, 2013
Abate by
Dec 16, 2013
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.242(b): Effective chip guarding and personal protective equipment was not used when compressed air was used for cleaning purposes.   On or about May 21, 2013 at 5166 Performance Drive, Cumming GA: The employees were exposed to an embolism hazard when they used a pistol type air gun that did not have an effective chip guard. The compressor registered 100 p.s.i. and employees used the compressed air for cleaning off tools, work surfaces, and themselves.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

1910.307 C

Serious Gravity 10 2 instances 2 exposed
Issued
Nov 19, 2013
Abate by
Feb 3, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:   On or about May 21, 2013 at 5166 Performance Drive, Cumming, GA:  Employees are exposed to an explosion hazard when:   a) Powder Coating Area - Electrical equipment including, but not limited to, overhead lights, electrical panels, disconnect switches, and outlets, in Class II, Division I locations, or a Class II, Division II location was not intrinsically safe for areas where dust accumulates on all surfaces.  b) Powder Coating Area - The Shop Vac used in the powder coating area was  not approved or safe for the hazardous location.
Recent events (2)
  • · I (S) $1680
  • · Z (S) $2800

View Professional Cryogenic Metallurgy & Coating, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339084196.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.