RIDGEFIELD, CT —
OSHA Inspection: CENTRAL CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CENTRAL CONSTRUCTION LLC in 593 MAIN STREET, RIDGEFIELD, CT 06877 (NAICS 238170). OSHA activity number 339084733.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CENTRAL CONSTRUCTION LLC
- Site address
- 593 MAIN STREET
- City
- RIDGEFIELD
- State
- CT
- ZIP
- 06877
- Mailing
- 18 SUMMIT DRIVE, MAHOPAC, NY 10541
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 F07
- Issued
- Jun 25, 2013
- Abate by
- Jul 15, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. Worksite: The employer did not ensure that the pump jack scaffold had been erected under the supervision of a competent person.
Recent events (1)
- — Z (S) $2000
1926.451 H01
- Issued
- Jun 25, 2013
- Abate by
- Jul 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(1): Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects. For falling objects too large, heavy or massive to be contained or deflected, the employer did not place and secure such potential falling objects away from the edge of the surface from which they could fall. Worksite: The employer did not ensure that toe boards were installed on the pump jack scaffold to prevent materials and other debris from falling onto employees who were walking through the front doorway below the scaffold.
Recent events (1)
- — Z (S) $0
1926.451 G01 VII
- Issued
- Jun 25, 2013
- Abate by
- Jul 3, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Worksite: An employee who was working from a pump jack scaffold was not protected from falling approximately 19 feet 1 inch to the ground below.
Recent events (1)
- — Z (S) $2800
1926.452 J02
- Issued
- Jun 25, 2013
- Abate by
- Jul 3, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. Worksite: An employee was working from a pump jack scaffold that was not braced at the bottom of the pump jack poles in an area where they could become displaced and collapse.
Recent events (1)
- — Z (S) $2800
1926.1053 B16
- Issued
- Jun 25, 2013
- Abate by
- Jul 8, 2013
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired. Worksite: Employees were using an aluminum extension ladder with a broken and split rung in order to gain access to the pump jack scaffold.
Recent events (1)
- — Z (S) $1200
More inspections at Central Construction LLC
View Central Construction LLC's full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339084733.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.