NIKISKI, AK ·
OSHA Inspection: XTO ENERGY INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of XTO ENERGY INC in PLATFORM A, NIKISKI, AK 99635 (NAICS 211111). OSHA activity number 339085508.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- XTO ENERGY INC
- Site address
- PLATFORM A
- City
- NIKISKI
- State
- AK
- ZIP
- 99635
- Mailing
- 52260 WIK ROAD, KENAI, AK 99611
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 211111
- Employees
- 7
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.304 B03 I
- Issued
- Jun 4, 2013
- Abate by
- Jul 2, 2013
- Penalty
- Initial $2,550 · Current $2,550
General-duty citation text
29 CFR 1910.304(b)(3)(i): All 125-volt, single-phase, 15- and 20-ampere receptacles installed in bathrooms or on rooftops shall have ground-fault circuit-interrupter protection for personnel. XTO Platform A, Third Floor Laundry and Wash Room: On or about 21 May 2013 and times prior thereto, the 120 electrical outlets located near sink and beside clothing washer/dryer and was not ground-fault circuit-interrupter protected. This condition exposed employees to an electrical shock and burn hazard.
Recent events (2)
- · I (O) $2550
- · Z (S) $2550
1910.304 G05
- Issued
- Jun 4, 2013
- Abate by
- Jun 4, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective. XTO Platform A, Welding shop: On or about 21 may 2013 and times prior thereto, the 120 volt Milwaukee band saw, C05AD11191170, missing the ground pin. This condition exposed employees to an electrical shock and burn hazard.
Recent events (2)
- · I (O) $0
- · Z (S) $0
More inspections at XTO Energy INC
View XTO Energy INC's full OSHA safety record →
More inspections in this industry (NAICS 211111)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339085508.